7 assembly – Trebor SS40LX-A Series Surge Suppressor User Manual

Page 7

Advertising
background image

SS40 SURGE OPERATION / MAINTENANCE MANUAL

PAGE 7

Insert small flat blade screwdriver in center hole of push plate to prevent

shaft from turning. Remove push plate by rotating it CCW.

Remove pilot valve boss using 3/4” pin tool to rotate boss CCW.

Disassemble pilot boss assembly and replace pilot assembly or other worn

parts.

Check .020 diameter air bleed port in back wall of suppressor for possible

blockage.

NOTE: All polypropylene and PTFE parts, when disassembled, should be
thoroughly washed and free from acid residue for handling purposes.

2.7 ASSEMBLY

Check that all parts are clean and dry.

Use a new pair of protective gloves to prevent carry over contamination.

Reverse disassembly procedure starting with reassembling pilot boss

assembly.

Before reinstalling diaphragms, check diaphragms for white colored creases

or other signs of wear or damage. Replace if necessary.

Complete reassembly by re-

clocking 1/16” diameter mark in head to the

original position. (Failure to do so will result in air fitting misalignment after
mounting suppressor.)

Retorque union nut using strap wrench and torque wrench to 65 ft-lbs.

Reinstall suppressor on pump to hand tight plus 1/4 turn. If connection

leaks, increase an additional 1/8 turn only. If leaking cannot be stopped,
remove suppressor, replace disk seal and check mating surfaces for
scratches or depressions.

Advertising