XPAR Heaters
Step 1: Scribe a mark into the mounting

surface indicating where the top part of

the mounting bracket will be located after

installation (Figure 8).

FIGURE 8 - SCRIBE THE TOP OF THE MOUNTING BRACKET

Step 2: Measure down 0.625” (16 mm) from the

scribed mark and scribe a mark for the top bolt

location. Measure an additional 5.5” (140 mm)

from the top bolt location to indicate the bottom

bolt location (Figure 9). Drill holes at the marked

locations for the mounting bolts.

FIGURE 9 - MEASURE AND SCRIBE THE TOP AND BOTTOM HOLE

LOCATIONS AND DRILL HOLES

Step 3: Pre-install the mounting bolts onto the

mounting surface allowing enough clearance to

slide the mounting bracket under the head of

the supplied bolts. Position the heater onto the

mounting bolts and tighten securely (Figure 10).

FIGURE 10 - POSITION HEATER ONTO MOUNTING BOLTS

NOTE: Proper use of supplied mounting bracket will

ensure minimum distance of 1” (25 mm) from the

mounting surface.

CAUTION

NEVER INSTALL ONE HEATER ABOVE

THE OTHER.
TO ENSURE SAFE OPERATION, HEATER MUST

BE INSTALLED, AS SHOWN IN FIGURES 11,

12 & 13. INSTALLATION WITH FINS IN THE

INCORRECT ORIENTATION MAY RESULT IN AN

UNSAFE CONDITION (REFER TO TABLE 2).

WARNING

IMPROPER ORIENTATION OF THE HEATER

COULD AFFECT THE SAFE AND RELIABLE

OPERATION OF THE HEATER.

YES

NO

NO

FIGURE 11 - XPAL AND XPAS HEATER

MOUNTING ORIENTATIONS - HORIZONTAL ONLY

YES

YES

NO

FIGURE 12 - XPAL AND XPAS HEATER

MOUNTING ORIENTATIONS - HORIZONTAL AND SIDE MOUNT

YES

NO

FIGURE 13 - XPAR HEATER

MOUNTING ORIENTATION - VERTICAL ONLY