System configurations main features, Solution for, I t-dualscan – ORBIT FR T-DualScan User Manual

Page 2: Measurement capabilities, Frequency bands, Scan area, Probe array oversampling capability, Software, Equipment, Add on

Advertising
background image

119

T-DualScan is an innovative planar near-field system that offers the best compromise between
accuracy, flexibility and measurement speed. The tower positioner can rotate 180° to switch easily
from the single-probe set-up (0.8 - 110 GHz) to the multi-probe set-up (0.8 - 18 GHz). T-DualScan
can also be offered as an upgrade to existing installations.

Technology

•

Near-field / Planar

•

Near-field / Cylindrical

Measurement capabilities

•

Gain

•

Directivity

•

Beamwidth

•

Cross polar discrimination

•

Sidelobe levels

•

3D radiation pattern

•

Radiation pattern in any polarization (linear or circular)

•

Antenna efficiency

•

Beam pointing properties

Frequency bands

•

Single-probe: 800 MHz - 110 GHz

•

Multi-probe: 800 MHz - 18 GHz

•

Multi-probe: 70 - 800 MHz on request

Scan area

•

Multi-probe: up to 12 m Y axis (1 m module)

•

Single-probe: up to 15 m Y axis (1 m module)

•

X-axis length depends on customer requirement

Probe array oversampling capability

•

Movement of the probe array on the vertical axis

Software

Measurement control, data acquisition and post processing

■

MiDAS

SatEnv

959 Spectrum (North America only)

Equipment

■

Amplification unit

■

Mixer unit

■

N-PAC

■

Primary synthesizer

■

Auxiliary synthesizer

■

Transfer switching unit

■

Power and control unit

■

Probe array power supply

■

Heavy DUT positioner

■

Elevation positioner for gantry arm

■

Positioner controller**

■

E-Stop unit

■

Local control unit**

■

Real time controller**

■

Control interface unit

■

Uninterruptible power supply

■

Instrumentation rack

■

Ethernet switch

AUT Port switch

Add on

■

Calibration kit (arm, reference antenna, positioner and interface)

Laser alignment instrumentation (laser inclinometer, laser tracker,

spin diode laser, laser pointer, digital spirit level and dial-indicator)

Absorbers*

Shielded anechoic chambers*

Accessories

Reference antennas (horns, standard gain horns, etc.)****

Probes****

Services

■

Installation and calibration

■

Warranty

■

Training

■

Project management

Post warranty service plans*****

MV-Cor

TM

correction table service***

* See AEMI/ Rainford EMC

Included

Optional

Required

Systems catalogs for more information

** See ORBIT/FR positioning equipment catalog for more information
*** See MV-CorTM service sheet for more information
**** See SATIMO & ORBIT/FR antenna catalog for more information
***** Refer to Orbit/FR service brochure for more information

System configurations

Main features

Easily switch from a single probe

to a multi-probe set-up

SOLUTION FOR

• Antenna Measurement
• Pulsed Measurement
• Phased Array Antenna Measurement

+

I T-DualScan

2

Advertising