System configurations main features, Solution for, I t-dualscan – ORBIT FR T-DualScan User Manual

Page 2: Measurement capabilities, Frequency bands, Scan area, Probe array oversampling capability, Software, Equipment, Add on

Advertising
background image

119

T-DualScan is an innovative planar near-field system that offers the best compromise between
accuracy, flexibility and measurement speed. The tower positioner can rotate 180° to switch easily
from the single-probe set-up (0.8 - 110 GHz) to the multi-probe set-up (0.8 - 18 GHz). T-DualScan
can also be offered as an upgrade to existing installations.

Technology

Near-field / Planar

Near-field / Cylindrical

Measurement capabilities

Gain

Directivity

Beamwidth

Cross polar discrimination

Sidelobe levels

3D radiation pattern

Radiation pattern in any polarization (linear or circular)

Antenna efficiency

Beam pointing properties

Frequency bands

Single-probe: 800 MHz - 110 GHz

Multi-probe: 800 MHz - 18 GHz

Multi-probe: 70 - 800 MHz on request

Scan area

Multi-probe: up to 12 m Y axis (1 m module)

Single-probe: up to 15 m Y axis (1 m module)

X-axis length depends on customer requirement

Probe array oversampling capability

Movement of the probe array on the vertical axis

Software

Measurement control, data acquisition and post processing

MiDAS

SatEnv

959 Spectrum (North America only)

Equipment

Amplification unit

Mixer unit

N-PAC

Primary synthesizer

Auxiliary synthesizer

Transfer switching unit

Power and control unit

Probe array power supply

Heavy DUT positioner

Elevation positioner for gantry arm

Positioner controller**

E-Stop unit

Local control unit**

Real time controller**

Control interface unit

Uninterruptible power supply

Instrumentation rack

Ethernet switch

AUT Port switch

Add on

Calibration kit (arm, reference antenna, positioner and interface)

Laser alignment instrumentation (laser inclinometer, laser tracker,

spin diode laser, laser pointer, digital spirit level and dial-indicator)

Absorbers*

Shielded anechoic chambers*

Accessories

Reference antennas (horns, standard gain horns, etc.)****

Probes****

Services

Installation and calibration

Warranty

Training

Project management

Post warranty service plans*****

MV-Cor

TM

correction table service***

* See AEMI/ Rainford EMC

Included

Optional

Required

Systems catalogs for more information

** See ORBIT/FR positioning equipment catalog for more information
*** See MV-CorTM service sheet for more information
**** See SATIMO & ORBIT/FR antenna catalog for more information
***** Refer to Orbit/FR service brochure for more information

System configurations

Main features

Easily switch from a single probe

to a multi-probe set-up

SOLUTION FOR

• Antenna Measurement
• Pulsed Measurement
• Phased Array Antenna Measurement

+

I T-DualScan

2

Advertising