ORBIT FR EMC-10 Anechoic Chamber User Manual

Emc - 10, 10 meter anechoic emc test chamber, Main features

Advertising
background image

Main features

Dimensions (shield): 21 m x 12 m x 8.5 m

30 MHz - 18 GHz frequency range

Fully

compliant design to meet CISPR, EN and

FCC requirements

Fully compliant for Immunity in accordance

with EN61000.4.3

ANSI C63.4 Emission Performance, NSA 30 MHz

-1 GHz +/-4 dB or better

Extended performance options 26 MHz - 40 GHz

HyPyr-Loss

TM

Ferrite and Hybrid absorbers

for 26 MHz - 40 GHz measurements

Optimized computer modeling to enable cost

effective absorber layouts

Bespoke and modular design enabling unlimited

performance options and facilitating upgrades
or relocations

Available as a turnkey package – chamber,

antenna & mast, turntables, Instrumentation
and software

SOLUTION FOR

EMC test sites requiring to meet Emission & Immunity standards

10 Meter Anechoic EMC Test Chamber

• Hybrid absorber technology

• High performance - minimum space

• Flexible, modular construction system

EMC - 10

+

Advertising