Salinity – LaMotte AG-104 Salt Water Aquarium User Manual

Page 14

Advertising
background image

SALINITY

QUAN TITY

CON TENTS

CODE

15 mL

*Salinity Indicator Reagent A

*7460-E

60 mL

*Salinity Titration Reagent B

*7461-H

60 mL

Demineralizer Bottle

1151

1

Test Tube, 5-10-15 mL, glass, w/cap

0778

1

Direct Reading Titrator, 0-20 Range

0378

1

Direct Reading Titrator, 0-1.0 Range

0376

*WARNING: Reagents marked with a * are considered to be potential health hazards.
To view or print a Material Safety Data Sheet (MSDS) for these reagents see MSDS
CD or www.lamotte.com. To obtain a printed copy, contact LaMotte by email, phone
or fax.

NOTE:

Read Demineralizer Bottle instructions and Direct Reading

Titrator Manual before performing test.
TEST RANGE:

0-20 ppt Salinity

Pro ce dure
1.

Fill test tube (0778) to 10 mL line with Demineralized Water
(1151).

2. Fill the 1.0 mL Titrator (0376) to 0 mark with sample water. Wipe

any excess water off the Titrator.

3. Dispense 0.5 mL of sample water into test tube by depressing

plunger until tip is at 0.5 mark. Discard remaining water in Titrator.

4. Add 3 drops of *Salinity Indicator Reagent A (7460). Cap and

gently swirl to mix.

5. Fill 0-20 Direct Reading Titrator (0378) with *Salinity Titration

Reagent B (7461). Insert Titrator in hole of test tube cap.

6. While gently swirling the tube, slowly depress plunger to titrate

sample until yellow color changes to pink-brown. Read test result
directly from the scale where the large ring on the Titrator meets
the Titrator barrel. Each minor Titrator division = 0.4 ppt Salinity.
EXAMPLE:

Plunger tip is 3 minor divisions below 10, test result is

10 plus (3 x 0.4) = 11.2 ppt.

14

Advertising