INDEX CALCULATION CHART

Total Dissolved Solids

Calcium Hardness &

Total Alkalinity

Temperature

ppm = CF

ppm = AF

°C = TF

0

9.70

10

1.00

0.0

2.60

100

9.77

25

1.39

4.0

2.50

200

9.83

50

1.70

8.0

2.40

300

9.85

75

1.87

12.0

2.30

400

9.86

100

2.00

16.0

2.20

600

9.87

150

2.15

20.0

2.10

800

9.89

200

2.30

25.0

2.00

1000

9.90

300

2.48

30.0

1.90

400

2.60

40.0

1.70

800

2.90

50.0

1.55

1000

3.00

¾

¾

EXAMPLE:

A water sample was tested and found to have the following

characteristics:

Test

Measured
Value

Factor

Factor Value
from Chart

Temperature

10.0°C

TF (Temperature Factor)

2.35

Total Dissolved
Solids

300 ppm

TDSF (Total Dissolved
Solids Factor)

9.85

Calcium Hardness

75 ppm

CF (Calcium Hardness
Factor)

1.87

Total Alkalinity

100 ppm

AF (Alkalinity Factor)

2.00

pH

8.5

pH

8.5

CALCULATIONS:

Soluability pH (pHS) = TF + TDSF - CF - AF

pHS = 2.35 + 9.85 - 1.87 - 2.00

pHS = 8.33

Langelier Saturation Index (LSI) = Measured pH - pHS

LSI = 8.5 - 8.33

LSI = 0.17

6