LaMotte AQ-2 Freshwater Aquaculture Kit User Manual

Fresh water aquaculture test kit

Advertising
background image

FRESH WATER AQUACULTURE

TEST KIT

MODEL AQ-3 · CODE 3634-03

NOTE:

Place dispenser Cap (0692) on *Mixed Acid

Reagent (V-6278). Save this cap for refills. It is important
to read the instruction manual before attempting to
perform the tests with the short form instructions provided
below.
*WARNING:

Reagents marked with a * are considered to

be potential health hazards. To view or print a Material
Safety Data Sheet (MSDS) for these reagents see MSDS
CD or www.lamotte.com. To obtain a printed copy, contact
LaMotte by e-mail, phone or fax.

To or der in di vid ual re agents or test kit com po nents, use the
spec i fied code num ber.

AMMONIA NITROGEN

1.

Fill test tube (0106) to 5 mL line with sample water.

2.

Add 4 drops Ammonia Nitrogen Reagent #1

(4797WT). Cap and mix. Wait 1 minute.

3.

Add 12 drops of *Ammonia Nitrogen Reagent #2

(4798WT). Cap and mix. Wait 5 minutes.

4.

Insert test tube into Octa-Slide Viewer (1100) with

Ammonia Nitrogen Octa-Slide Bar (3438) inserted.

5.

Record as ppm Ammonia Nitrogen (NH

3

-N).

NITRITE NITROGEN

1.

Fill test tube (0106) to 2.5 mL line with sample water.

2.

Dilute to 5 mL line with *Mixed Acid Reagent

(V-6278).

3.

Use 0.1g spoon (0699) to add 0.1g of *Color

Developing Reagent (V-6281). Cap and mix for 1

minute. Wait 5 minutes.

4.

Insert test tube into Octa-Slide Viewer (1100) with

Nitrite Nitrogen Octa-Slide Bar (3437) inserted.

5. Record as ppm Nitrate Nitrogen (NO

2

-

N).

5.

Record as ppm Nitrite Nitrogen (NO

2

-N).

ALKALINITY

1.

Fill titration tube (0608) to 5 mL line with sample

water.

2.

Add 4 drops of *BCG-MR Indicator (2311-EG). Cap

and mix. Sample will turn blue-green.

3.

Fill Direct Reading Titrator (0382) with *Alkalinity

Titration Reagent B (4493DR).

4.

Ti trate sam ple un til blue-green color changes to pink.

5.

Re cord as ppm Alkalinity (CaCO

3

).

5.

Record as ppm Alkalinity (CaCO

3

).

CARBON DIOXIDE

1.

Fill titration tube (0608) to 20 mL line with sample

water.

2.

Add 2 drops *Phenolphthalein Indicator, 1% (2246). If

sample turns red, no free carbon dioxide is present. If

colorless, proceed to Step 3.

3.

Fill Direct Reading Titrator (0380) with *Carbon

Dioxide Reagent B (4253DR).

4.

Titrate sample until faint pink color persists for 30

seconds.

5.

Record as ppm Carbon Dioxide (CO

2

).

CHLORIDE

1.

Fill titration tube (0608) to 15 mL line with sample

water.

2.

Add 1 drop *Phenolphthalein Indicator, 1% (2246). If

sample is colorless, proceed to Step 3. If sample turns

pink, add *Sulfuric Acid, 0.5N (6090) one drop at a

time until pink color disappears.

3.

Add 3 drops *Chloride Reagent #1 (4504). Cap and

mix. Sample will turn yellow.

4.

Fill Direct Reading Titrator (0382) with *Chloride

Reagent #2 (4505DR).

5.

Titrate sample until yellow color first changes to orange

or orange-red.

6.

Record as ppm Chloride (Cl).

HARDNESS

1.

Fill titration tube (0608) to 12.9 mL line with sample

water.

2.

Add 5 drops of *Hardness Reagent #5 (4483). Cap and

mix.

3.

Add 5 drops of *Hardness Reagent #6 (4485). Cap and

mix. Sample will turn red.

4.

Fill Direct Reading Titrator (0382) with Hardness

Reagent #7 (4487DR).

5.

Titrate sample until red color changes to clear blue.

6.

Record as ppm Total Hardness (CaCO

3

).

LaMOTTE COM PANY

Helping Peo ple Solve An a lyt i cal Challenges

SM

PO Box 329 · Chestertown · Mary land · 21620 · USA

800-344-3100 · 410-778-3100 (Out side U.S.A.) · Fax 410-778-6394 · www.lamotte.com

63634-03-SF · 2.07