LaMotte AST Series Professional Soil Test Outfits User Manual

Page 33

Advertising
background image

PROCEDURE
1.

Use pipet (0364) to add 2 drops of soil extract to the large
depression on a spot plate (0159).

2.

Add 2 drops of deionized water.

3.

Use a clean pipet (0364) to add 1 drop of *Aluminum Test Solution
(5101). Use a stirring rod (0519) to mix. Wait one minute.

4.

Match sample color to a color standard on the Aluminum in Soil
Color Chart (1301). Record result. Use chart below to convert
reading to an approximate concentration. Record as ppm
Aluminum.

Very Low

5 ppm

Low

10 ppm

Medium

30 ppm

High

80 ppm

Very High

125 ppm

33

Advertising