ALKALINITY P&T KIT

DIRECT READING TITRATOR, 0-200 ppm

CODE 4533-DR-01

QUANTITY

CONTENTS

CODE

100

Phenolphthalein Tablets

T-2246-J

100

BCG-MR Indicator Tablets

T-2311-J

60 mL

*Alkalinity Titration Reagent B

*4493DR-H

1

Test Tube, 5-10-15 mL, glass, w/cap

0778

1

Direct Reading Titrator, 0-200 Range

0382

*WARNING: Reagents marked with an * are considered to be potential health hazards.
To view or print a Material Safety Data Sheet (MSDS) for these reagents go to
www.lamotte.com. To obtain a printed copy, contact LaMotte by e-mail, phone or fax.

To order individual reagents or test kit components,
use the specifi ed code number.

NOTE: Read the Direct Reading Titrator Instruction
Manual (1649) before proceeding. Each minor
division on the Titrator scale equals 4 ppm CaCO

3

.

PHENOLPHTHALEIN (P) ALKALINITY PROCEDURE

1. Fill test tube (0778) to 5 mL line with sample water.
2. Add one Phenolphthalein Tablet (T-2246). Cap and mix until tablet disintegrates.

If solution does not turn red, P Alkalinity is 0. If solution turns red, proceed to Step 3.

3. Fill the Direct Reading Titrator (0382) with *Alkalinity Titration Reagent B

(4493DR). Insert Titrator into center hole of test tube cap.

4. While gently swirling tube, slowly press plunger to titrate until red color disap-

pears. Read the test result directly from the scale where the large ring on the Titra-
tor meets the Titrator barrel. Record as ppm P Alkalinity as CaCO

3

.

EXAMPLE: Plunger tip is 3 minor divisions below line 80. The test result is 80
plus 12 (3 divisions x 4) equals 92 ppm.

5. If plunger tip reaches the bottom line on the Titrator scale (200 ppm) before the

color change occurs, refi ll the Titrator and continue the titration. When recording
test result, be sure to include the value of original amount of reagent dispensed
(200 ppm).
NOTE: Do not move Titrator plunger after the P Alkalinity endpoint has been
obtained. The titration is continued in the T Alkalinity procedure.

TOTAL (T) ALKALINITY PROCEDURE

6. Being careful not to move plunger, remove Titrator and cap from test tube con-

taining sample that was titrated in Step 4.

7. Add one BCG-MR Tablet (T-2311). Cap and shake until tablet disintegrates.

Solution will turn green-blue.

WARNING! This set contains chemicals

that may be harmful if misused. Read

cautions on individual containers

carefully. Not to be used by children

except under adult supervision