LaMotte DPD CHLORINE TEST KIT LP-1-NMC User Manual

Page 2

Advertising
background image

PRO CE DURE

FREE AVAILABLE CHLORINE
1.

Rinse the test tube (0106) with sample water. Fill to 10 mL line with
sample water.

2.

Add one *Chlorine DPD #1R Tablet (6999A). Cap and mix until
tablet disintegrates.

3.

Immediately insert test tube into Chlorine DPD Comparator (6978).
Match sample color to a color standard. Record as Reading #1. Do
not discard this sample if testing for Monochloramine, Dichloramine
or Total Residual Chlorine.
NOTE:

Reading should be made within one minute of adding

reagent.

Reading #1 = ppm Free Available Chlorine

MONOCHLORAMINE
4.

Add one Chlorine DPD #2R Tablet (6904A) to sample from Step 3.
Cap and mix until tablet disintegrates.

5.

Insert test tube into Chlorine DPD Comparator (6978). Match
sample color to a color standard. Record as Reading #2.

Reading #2 - Reading #1 = ppm Monochloramine

DICHLORAMINE AND TOTAL RESIDUAL CHLORINE
6.

Add one *Chlorine DPD #3R Tablet (6905A) to sample from Step 5.
Cap and mix until tablet disintegrates.

7.

Insert test tube into Chlorine DPD Comparator (6978). Match
sample color to a color standard. Record as Reading #3.

Reading #3 - Reading #2 = ppm Dichloramine

Reading #3 = ppm Total Residual Chlorine