Wiring: 9-pin connector cont – Crimestopper Security Products CS-2012DP-TW1 User Manual

Page 5

Advertising
background image

5

WIRING: 9-PIN Connector Cont.


Green/Red: (-) 500mA Remote Aux. Output 1 (Optional, requires relay)
This is a programmable output that can operate two different ways: 1. (DEFAULT) A Remote Auxiliary Output that
provides a ½ second (-) Negative pulse when Button #3 is pressed to open a Factory power trunk or hatch release.

GREEN/RED

85

86

30

87

Trunk Soleniod

Dome Light

NEGATIVE AUXILARY OUTPUT

OR *

+12V CONSTANT

+12V CONSTANT

-OR-

Aux Function

* Test activation circuit in vehicle.

Connect to+12V for Positive circuits

or Ground for Negative circuits. Relay

not included.

(-) AUX OUTPUT

OR

-OR-





Blue/Black: (-) 500mA IGNITION OUT or REMOTE AUX. Output #2 (Programmable Option #17)
This wire functions as a Negative IGNITION OUTPUT (Ground while Remote Starting) for use when connecting
factory Security Bypass modules or when an additional external Ignition Relay is required for your installation. This
wire can be programmed to function as an AUXILIARY OUTPUT #2 providing a momentary (-) Negative output
when Button #5 then #1 is pressed and held for more than 2 seconds. The Aux Channel #2 output stays on as long
a the button is held down. Connect to the Negative activation circuit of an auxiliary module or device.

Advertising
This manual is related to the following products: