LaMotte DUO-SOFT User Manual
Page 6
PRO CE DURE D - RE GEN ER A TION OF RESIN IN BOTTOM CHAM BER
Follow manufacturers’ instructions for regeneration of media. Cation exchange resin
may be regenerated in the following manner.
At this point the resin in the bottom chamber should be
completely regenerated.
9.
Clean
threaded area
completely
and replace
black plug in
bottom of
softener.
6.
Wash resin with
approximately 1
gallon of tap
water.
8.
Attach adapter
to faucet.
7.
Turn
softener
upside down
and remove
black plug
from bottom
of softener.
2.
Prepare salt
solution by
dissolving
about ½ pound
of salt (sodium
chloride) in 1
quart of water.
1.
Prop up the softener. Allow to
stand for about 30 minutes.
4.
30
MINU
TES
Clamp inlet
tube.
Add salt
solution until
softener is
completely
full.
3.
Unclamp inlet
tube and allow salt
solution to run to
waste.
5.