LaMotte DUO-SOFT User Manual

Page 6

Advertising
background image

PRO CE DURE D - RE GEN ER A TION OF RESIN IN BOTTOM CHAM BER

Follow manufacturers’ instructions for regeneration of media. Cation exchange resin
may be regenerated in the following manner.

At this point the resin in the bottom chamber should be

completely regenerated.

9.

Clean

threaded area

completely

and replace

black plug in

bottom of

softener.

6.

Wash resin with

approximately 1

gallon of tap

water.

8.

Attach adapter

to faucet.

7.

Turn

softener

upside down

and remove

black plug

from bottom

of softener.

2.

Prepare salt

solution by

dissolving

about ½ pound

of salt (sodium

chloride) in 1

quart of water.

1.

Prop up the softener. Allow to

stand for about 30 minutes.

4.

30

MINU

TES

Clamp inlet

tube.

Add salt

solution until

softener is

completely

full.

3.

Unclamp inlet

tube and allow salt

solution to run to

waste.

5.