INSTALLATION

WARNING:

IMPROPER INSTALLATION CAN RESULT IN

DEATH OR SERIOUS PERSONAL INJURY! This accessory
should be installed by qualified personnel.

Site Preparation

Locate and Prepare Mounting Site

1.

Identify a suitable wall location for the in-wall enclosure.

IMPORTANT ! : The PAC-501 is designed for in-wall
installation spanning a minimum of three wood studs, 16"
on center. Installation of PAC-501 in 2x4 wall results in
nearly direct contact with vertical studs and back wall.
Inadequate space will remain for electrical wires/cables,
plumbing, ductwork, or insulation. Locate installation
accordingly.

WARNING:

ELECTRICAL SHOCK HAZARD! CUTTING

OR DRILLING INTO ELECTRICAL WIRES OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surfaces is free
of electrical wires and cables before cutting, drilling, or
installing fasteners.

WARNING:

EXPLOSION AND FIRE HAZARD! CUTTING

OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY! ALWAYS make certain
area behind mounting surfaces is free of gas, water, waste, or
any other plumbing before cutting, drilling, or installing
fasteners.

2.

Using a stud sensor, locate and mark studs.

3.

Center and level housing between marked studs.

4.

Using housing as a template, draw pencil line completely
around housing. (See Figure 1)

5.

Cut drywall on outside edge of line and remove.

Figure 1

Frame Housing

The exposed portion of the center wood stud must be removed
and the resulting cavity completely framed with wood. The
following steps are suggested. The actual procedure is
dependent upon the specific installation.

WARNING:

STRUCTURAL FAILURE HAZARD! FAILURE

TO TAKE ADEQUATE PRECAUTIONS CAN LEAD TO
DEATH OR SERIOUS INJURY! Ensure removal of center
stud will not cause unacceptable loss of structural strength.
Consult a qualified building contractor and applicable building
codes.

1.

Remove exposed portion of center wood stud flush with
upper and lower drywall edges.

Figure 2

Wood Studs

(A)

Horizontal Framing

Support
Blocks

Top View

Wood
Screws
(5 places)

(Typical for each
support block)