ClearOne Converge Pro Serial User Manual
Page 56

283
SPEEDDIAL – Speed Dial a Number
This command dials a speed dial number.
Command Form
: DEVICE SPEEDDIAL <Channel> [Value]
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17 (R)
-
Value
Unsigned Integer
2
1 – 20
(Null to query in text)
-
STRING – String Execution
This command sends the specified string out the serial port.
Command Form
: DEVICE STRING [ID]
Argument Type
Size
Values
Units
ID
Unsigned Integer
4
0 – 7
(Null to query last string in text)
-
SYSCHECKS – System Checks
Initiates the system checks. There is no query for this command.
The System Check integer bits determine which tests are run. Each bit set generates a separate SYSRESULT
response.
COMMAND FORM
: DEVICE SYSCHECKS <System Check>
Argument Type
Size Values
System
Check
Hexadecimal
Integer
4
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Network
Telephone
Mic 1
Mic 2
Mic 3
Mic 4
Mic 5
Mic 6
Mic 7
Mic 8
All other bits reserved
Packet Loss Statistics
SIP Proxy Registration Status
Power Amp Fault Check
Power Amp Temp Check