Procedure summary, Rocedure, Ummary – ClearOne Converge USB User Manual
Page 7

QUICK-START GUIDE
5
Procedure Summary
These steps, detailed in the subsequent sections, must be done in the
following order to use the CONVERGE USB in your CONVERGE Pro Site:
1. Verify the CONVERGE Pro firmware is at version 4.X or higher.
Update if needed using CONVERGE Console.
2. Select the Expansion bus (E-bus) Link Channels by connecting a
terminal block to the CONVERGE USB Control/Status connector at
the back of the device.
Note: Not required if the CONVERGE USB is to be used only as
a E-bus extender with no USB In/Out channels. Steps for “Link
Channel Selection” are described later in this document.
3. Connect the CONVERGE USB to the updated CONVERGE Pro/SR
via the E-bus.
4. Route the CONVERGE USB Transmit and Receive audio channels
with CONVERGE Console.
Note: Not required if the CONVERGE USB is to be used only as a
E-bus extender with no USB Tx/Rx channels
.
5. Configure and set audio controls on the PC/Laptop or
COLLABORATE Room codec.