CLOCK – Clock Set
This command sets or reports the current time.
ARGUMENT DETAILS
Name
Type
Size
Values
Date
Unsigned Integer
1
1 – 31
Month
Unsigned Integer
1
1 – 12
Year
Unsigned Integer
2
2000 – 2099
(NULL to Query in Text)
Hours
Unsigned Integer
1
00 – 23
Minutes
Unsigned Integer
1
00 – 59
Seconds
Unsigned Integer
1
00 – 59
Day of Week
Unsigned Integer
1
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
TEXT FORM DETAILS
COMMAND FORM:
DEVICE CLOCK [Date Month Year Hours Minutes Seconds Day]
COMPRESS – Compressor
This command selects/reports the compressor configuration.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
5 (P)
Threshold
Signed Integer
1
-60 – 20 dB
(Null to query in text)
Ratio
Unsigned
Integer
1
1 – 20
Attack
Unsigned Float
2
0.00 – 100.00 ms
Release
Unsigned
Integer
2
100 – 2000 ms
Gain
Unsigned Float
4
0.00 – 20.00 dB
TEXT FORM DETAILS
COMMAND FORM:DEVICE COMPRESS <Channel> [Threshold Ratio Attack Release Gain]