Troubleshooting – Chicago Electric 66910 User Manual

Page 13

Advertising
background image

Page 13

For technical questions, please call 1-800-444-3353.

SKU 66910

tROuBlESHOOtIng

tO PREVEnt SERIOuS InJuRy FROM aCCIDEntal OPERatIOn
OR ElECtRIC SHOCK:

turn the Power Switch (42) of the Chipper Shredder to its “OFF” position and
unplug the unit from its electrical outlet before performing any inspection,
maintenance, or cleaning procedures.

Problem

Possible Cause(s)

likely Solution(s)

Chipper Shredder will not
start.

No power at outlet.

1.

Power Cord (37) not

2.

connected.
Circuit Breaker (39) has

3.

tripped.

Knobs (11) are loose.

4.

Check power at outlet.

1.

Check that Power Cord (37) is

2.

plugged in.

Clean debris inside Hopper

3.

(1), Main Housing (14), and
Chute (67). Tighten Knobs

(11) firmly*. Then reset circuit
breakers and restart.

Check that Knobs (11) are

4.

firmly tightened*.

no cutting action.

Unit is clogged with debris.

1.

Blades dull or damaged.

2.

Clean out all debris from unit.

1.

Replace damaged blades.

2.

Motor sounds as if it is not
running properly. Circuit
Breaker (39) trips.

Unit is clogged with debris.

Clean out all debris from unit.

Chipper Shredder shuts off for
no apparent reason.

Knobs (11) are loose.

Clean out all debris from unit.

Check that Knobs (11) are firmly

tightened*. Then restart.

*nOtE: The vibration of the unit
during normal use will cause
the Knobs to loosen and allow
the Main Housing (14) to lift up
off the Safety Shut-Off Switch
(55), turning off the Motor (47)
for safety. Tightening the Knobs

firmly will engage the Safety
Shut-Off Switch and allow the
unit to again start and run.

Advertising