CFM CX1000 User Manual

Page 2

Advertising
background image

3

2

IMPORTANT SAFETY INSTRUCTIONS

Always unplug the CX1000 when it is not in operation, while the filters or
UV light are being changed, and when cleaning the unit.

After servicing the unit, both the front and top grill assemblies must be
reinstalled in exactly the same manner as prior to removal. If either grill
is not reinstalled properly, the CX1000 will not function. This is a built- in
safety feature.

Before using the CX1000, extend the power cord and inspect for any signs
of damage. Do not use the unit if the power cord has been damaged.

Warning - This appliance is designed to be used on a flat and level sur-
face, and may not work properly on an uneven surface. To reduce the risk
of electric shock and injury, do not place in a window. Always place the
CX1000 at least 12 inches (30 centimeters) away from heat sources such
as stoves, radiators, or heaters.

Do not move the CX1000 while it is in operation. Always unplug the unit
prior to moving it.

Do not immerse the CX1000 in water, as permanent damage will occur.

Read and save these instructions.

SPECIFICATIONS

Manufacturer:

Continental Fan Manufacturing Inc.

Model:

CX1000

Voltage:

1/120V/60

Dimensions:

21.5" W x 18.0" H x 8.0" D

Maximum Amps:

0.95

Maximum Watts:

110

Max Air Flow:

265 cfm

UV Range:

254 NM (germicidal)

Weight:

23 LBS

Application:

1000 sq. feet (auto mode)
2000 sq. feet (super mode)

Catalyst:

Titanium Dioxide

Pre-Filter:

5 micron

HEPA Filter:

0.3 micron hospital grade

Service:

UV LAMP - 1 year
FILTERS - 2 years

TABLE OF CONTENTS

IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . .3

SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

UNPACKING THE CX1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

INSTALLING THE CX1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

USING THE CX1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

SELECT ROOM SIZE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

SELECT OPERATING MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

MONITORING OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

SERVICE PANEL INDICATOR LIGHTS . . . . . . . . . . . . . . . . . . . . . . . . . . .8

UV LAMP INDICATOR LIGHTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

FILTER INDICATOR LIGHTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

PERFORMING MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

REPLACING THE UV LAMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

REPLACING THE FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

LIMITED LIFETIME WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11