14 |

Troubleshooting |

IS40/Triton System Installation Manual

Troubleshooting

Issue

Solution

Unit does not power
up

•

Check that the NMEA 2000/SimNet
network has 12 V connected.

•

Try connecting to a different network
cable in case power wires damaged
internally.

Unit does not show
data for a specific
source

•

In the advanced setup menu, select
sources, and manually select the
required data source.

•

Check the network connection on the
data source.

Unit does not show
any data from any
connected source
or
Unit data sources
intermittently drop
out.

•

In the advanced setup menu, select
sources option, then select AUTO
SELECT.

•

Check the Device List menu and see if
any devices are detected.

•

Try connecting to a different network
cable in case data wires damaged
internally.

•

In the advanced setup menu, check
the diagnostics page to see if any
errors are occurring.

•

Check network topology and
termination rules are correctly
implemented.

•

Disconnect other devices from
network, one-by-one, starting with
3rd party devices.