177

s = 0 for automatic output disabled
s = 1 for automatic output enabled at 2Hz
s = 2 for automatic output enabled at 4Hz

Sets or resets automatic output flag for basic raw data.
Automatic output is started using the

#

OS,1(CR) command.

Basic data is then output every half second as follows:

B,w...w,x...x,y...y,z...z(CR)
www.w = Boatspeed in Hz uncalibrated, 5 characters
xxx.x = Apparent Windspeed in Hz uncalibrated, 5
characters.
yyy.y = Apparent Wind Angle in degrees no offset, 5
characters
zzz.z = Heading in degrees after application of offset, 5
characters

If #OS,2(CR) is used basic data will be output every quarter
of a second.

5.15.9 Immediate Output of Basic Data

####

OB(CR)

This command stops all automatic output of other data and
outputs basic data immediately. Data is output using the
same format as automatic output of basic data.

Note

•

After automatic data has been stopped by this command

it can be restarted using the

####

OS,1(CR) command.

5.15.10 Immediate Output of Channel or Remote
Data

####

OI,nn,s(CR)

Advertising