BaseStation 1000 Irrigation Controller Manual

Zero reading

•

The biSensor detection blade is damaged – if the soil temperature

reading is valid, replace the biSensor.

If the following conditions occur in the area where the biSensor is buried, you might get unusual or

inaccurate readings from the biSensor. Review these conditions along with causes and suggestions

for resolving the issues.

Condition

Causes/Action

Ground is too

dry with low

biSensor

moisture

reading

•

Not enough zone water time – increase water time to apply at least ½

inch of water

•

biSensor not being watered by its primary zone – change the assignment

or move the biSensor to the correct location

•

Program start times are too infrequent – increase the program start

time frequency

•

biSensor limit is too low – raise limit or run a biSensor calibration cycle

Ground is too

dry with high

biSensor

moisture

reading

•

biSensor not being watered by its primary zone – change the assignment

or move the biSensor to the correct location

•

biSensor is buried too deep – rebury the biSensor to be only 3 inches

deep

Ground is too

wet with high

biSensor

moisture

reading

•

biSensor is buried in low area where water collects – move biSensor

from low area

•

biSensor not being watered by its primary zone – change the assignment

or move the biSensor to the correct location

•

Program start times are too often – increase the interval between start

times

•

biSensor limit is too high – lower limit or run a biSensor calibration cycle

Ground is too

wet with low

biSensor

moisture

reading

•

biSensor not being watered by its primary zone – change the assignment

or move the biSensor to the correct location

•

biSensor is buried too deep – rebury the biSensor to be only 3 inches

deep

•

Not enough zone water time – increase water time to apply at least ½

inch of water