Even Days
This day interval mode will allow programs to
start on even days of the month.
Odd Days
This day interval mode will allow programs to
start on odd days of the month.
Odd Days and Skip 31
st
This day interval mode will allow programs to start on odd days of the month, but will also not
allow watering on the 31
st
of the month, thus maintain a better every two day schedule when
crossing to a new month.
Soak Cycle
Please see a previous section for this
information. Refer to page 36, Using Soak cycles.
MV/Pump Start
This dial position can be used to assign master
valves to the corresponding mainline, and to also
assign programs to the appropriate mainline.
This screen shown to the right is nearly a duplicate of the mainline configure screen in the Flow
Menu dial position. Normally closed master valves have a vale decoder assigned to them in the
biCoder menu dial position, and then they are assigned to a mainline in this screen. Normally
Open Master Valves (shown in MV1 in this sample screen) are based on the flow device number
(#1 in this case). For additional information, refer to page 48, Multiple Flow Devices and
Mainlines.