BE Pressure supply 2" Fire Fighting Cart HPFC-2070R User Manual
Page 17

17
Starting the Water Pump
Use the following start instructions:
1. Make sure unit is on a flat, level surface and pump chamber is primed.
2. Turn fuel valve (1) to “On” position. The fuel valve handle will be
vertical (pointing toward the ground).
3. Push on/off switch (2) to “On” position.
4. Move engine speed lever (3) to “Fast” ( ) position.
6. Grasp recoil handle and pull slowly until slight resistance is felt. Then
pull handle rapidly to overcome compression, prevent kickback and
start engine.
5. Move choke lever (4) to “On” position.
starting
the
water
pump
2
3
4
WARNING
Starter cord kickback (rapid retraction) can result in
bodily injury. Kickback will pull hand and arm toward
engine faster than you can let go.
Broken bones, fractures, bruises, or sprains could
result.
• When starting engine, pull cord slowly until resistance is felt and then
pull rapidly to avoid kickback.
1
- 2" Fire Fighting Cart HPFC-2065HR 3" Chemical Transfer Pumps NP-3070R 3" Chemical Transfer Pumps NP-3065HR 2" Semi-Trash Pumps TP-2070RT 2" Trash Pumps TP-2065HM 3" Semi-Trash Pumps TP-3065HR 2" Semi-Trash Pumps TP-2065HT 4" Water Transfer Pumps WP-4013HR 1" Water Transfer Pumps WP-1015HT 2" High Pressure Pumps HP-2070R 2" High Pressure Pumps HP-2065HR 3" Semi-Trash Pumps TP-3070R 3" Trash Pumps TP-3013HM 3" Water Transfer Pumps WP-3065HL 2" Water Transfer Pumps WP-2065HL 1" Water Transfer Pumps WP-1020R 3" Water Transfer Pumps WP-3070S 2" Water Transfer Pumps WP-2070S 2" Chemical Transfer Pumps NP-2065HR 2" High Pressure Pumps HP-2015R 2" Fire Fighting Pumps Kits HPFK-2065HR 2" Fire Fighting Pumps Kits HPFK-2070R 4" Water Transfer Pumps WP-4015R 2" High Pressure Pumps HP-2013HR 3" Trash Pumps TP-3065HR 4" Trash Pumps TP-4013HM 2" Chemical Transfer Pumps NP-2070R 4" Trash Pumps TP-4015RM 3" Trash Pumps TP-3015RM 2" Chemical Transfer Pumps NP-2050HR 2" Water Transfer Pumps Kits WPK-2065CM 2" Water Transfer Pumps - WP-2050HL