Maintenance, Caution, Warning – BE Pressure supply 10 Gallon Vertical Air Compressor AC2010 User Manual
Page 18
![background image](/manuals/600114/18/background.png)
18
maintenance
Maintenance
WARNING
Disconnect electrical cord from outlet and release air pressure from
system before performing maintenance.
NOTE:
All compressed air systems contain maintenance parts (e.g.
lubricating oil, filters, separators), which are periodically replaced. These
used parts may be, or contain, substances that are regulated and must
be disposed of in accordance with local, state, and federal laws and
regulations.
NOTE:
Take note of the position and locations of parts during disas-
sembly to make reassembly easier. The assembly sequences and parts
illustrated may differ for your particular unit.
Daily or before each operation
·· Check lubrication levels. Fill as needed.
·· Drain receiver tank condensation.
·· Check for unusual noise or vibration.
·· Ensure area around compressor is free from rags, tools, debris, and
flammable or explosive materials.
Weekly
·· Check safety/relief valves by pulling rings. Replace safety/relief valves
that do not operate freely.
·· Inspect air filter element. Clean if necessary.
1. Before maintenance operation, stop the
air compressor, cut off power supply and
discharge all air in the air tank.
2. Clean crank case and renew lubricating oil
after the first 10 working hours.
3. Check the oil level daily and replenish if
necessary (Fig.5).
4. Clean crank case and renew the oil, clean
air filter every three months or 120 hours.
5. Open the drain cock under the tank to
exhaust the condensate daily
6. Check the safety valve and pressure gauge
every 6 months and make sure they are in
correct condition.
7. Make sure there is no rust on the air tank
and the air tank is not damaged.
FIG. 4