Maintenance, Caution, Warning – BE Pressure supply 10 Gallon Vertical Air Compressor AC2010 User Manual

Page 18

Advertising
background image

18

maintenance

Maintenance

WARNING

Disconnect electrical cord from outlet and release air pressure from

system before performing maintenance.

NOTE:

All compressed air systems contain maintenance parts (e.g.

lubricating oil, filters, separators), which are periodically replaced. These

used parts may be, or contain, substances that are regulated and must

be disposed of in accordance with local, state, and federal laws and

regulations.
NOTE:

Take note of the position and locations of parts during disas-

sembly to make reassembly easier. The assembly sequences and parts

illustrated may differ for your particular unit.

Daily or before each operation

·· Check lubrication levels. Fill as needed.

·· Drain receiver tank condensation.

·· Check for unusual noise or vibration.

·· Ensure area around compressor is free from rags, tools, debris, and

flammable or explosive materials.

Weekly

·· Check safety/relief valves by pulling rings. Replace safety/relief valves

that do not operate freely.

·· Inspect air filter element. Clean if necessary.

1. Before maintenance operation, stop the

air compressor, cut off power supply and

discharge all air in the air tank.

2. Clean crank case and renew lubricating oil

after the first 10 working hours.

3. Check the oil level daily and replenish if

necessary (Fig.5).

4. Clean crank case and renew the oil, clean

air filter every three months or 120 hours.

5. Open the drain cock under the tank to

exhaust the condensate daily

6. Check the safety valve and pressure gauge

every 6 months and make sure they are in

correct condition.

7. Make sure there is no rust on the air tank

and the air tank is not damaged.

FIG. 4

caution