Fddi devices – Cabletron Systems BRIM-F6 User Manual
Page 33
                                    Advertising
                                    
                                        
                                    
                                
                                 
FDDI Devices
BRIM-F6 User’s Guide
Page A-9
Figure A-6. Dual Homing Topology
Concentrator 3 in Figure A-6 has redundant connections to the main ring 
through either concentrator 1 or 2. The FDDI connection rules only 
permit one active connection, Port B. If a cable failure severs concentrator 
3’s connection to concentrator 2, CFM activates Port A.
A.6
FDDI Devices
FDDI recognizes four station configurations (SAS, DAS, DAC, and 
SAC). These configurations differ by the mix of FDDI entities within the 
station (see Figure A-7).
All stations must have:
•
one SMT
•
at least one MAC
•
one PMD
•
one PHY.
Port A
Port A
Port A
Port B
Port B
Port B
Port M
Port M
Port M
Port M
Primary
Connection
Backup
Connection
3
2
1
BRIM-F Book Page 9 Monday, January 29, 1996 9:26 AM