Bio-Rad Components for Older Model Spot Cutter User Manual

Page 35

Advertising
background image

In depositing spots to the microtiter plate, it is important to prepare the plates with liquid in
the wells. While deposit of the gel pieces does not depend on liquid in the wells, the
reproducibility of accurate deposits is improved with this condition. The liquid can be the
solution used as the first step in the digestion process, or any other liquid used in typical lab
conditions. The stainless steel cutting tip and polypropylene microtiter plates are compatible
with a wide variety of chemicals.

Technical Service

For technical assistance with the system including all hardware and software, contact

your local Bio-Rad office. All spare parts not listed in this document can be ordered by
contacting your local Bio-Rad office.

For inquiries and requests regarding system repair or service, contact your local Bio-Rad

office or distributor. Please have the following details available:

1. Instrument model and catalog number.

2. Serial number (located on the back of the system).

3. Hardware and software version information.

ProteomeWorks Spot Cutter Warranty Information

This warranty statement may vary outside of the continental United States. Please contact

your local Bio-Rad office for the exact terms of your warranty.

Bio-Rad Laboratories warrants to the customer that the ProteomeWorks Spot Cutter

System (catalog number 165-7009) will be free from defects in material and

workmanship and will meet all of the performance specifications for a period of one year
from the date of shipment. This warranty covers all parts and components of the instrument
except those such as gaskets, o-rings, batteries, and other items of normal wear that require
frequent replacement. This warranty does not cover items broken or damaged, including glass
or platinum electrodes, by improper handling or use.

If any defects should occur during this period, Bio-Rad Laboratories will either replace

or repair the defective parts free of charge. For the exact terms of warranty, please see the
Instrument Warranty Card.

In the event that the system must be returned to the factory for repair under warranty, the

instrument must be packed and returned in its original shipping container. If this is not
available, contact Bio-Rad Technical Service for instructions.

Bio-Rad shall not be liable for any incidental, special or consequential loss, damage or

expense, directly or indirectly arising from use of the ProteomeWorks Spot Cutter system.
Bio-Rad makes no warranty whatsoever in regard to products or parts furnished by third
parties, such being subject to the warranty of their respective manufacturers. Service under this
warranty shall be requested by contacting your nearest Bio-Rad office.

This warranty does not extend to any instruments or parts thereof that have been subject

to misuse, neglect, or accident, or that have been modified or serviced by anyone other than
Bio-Rad or its representative, or that have been used in violation of Bio-Rad instructions. It
also does not extend to instruments or parts thereof that have been used with fittings or other
spare parts not authorized by Bio-Rad Laboratories, that are interfaced to inappropriate
external devices, that have been exposed to inappropriate solvents, cleaning agents or samples.
The warranty also does not cover instrument damage resulting from facility problems such as
power surges.

32

Advertising