2 March 2014

6

3.1

Power

Before starting connect the supplied 12VDC power adapter or an external 9 - 24VDC power source to the power
connector as described in Section 2. The adapter supplied with your router is suitable for use with 120VAC 60-hertz wall
power. If you need a different power solution contact Ctek.

3.2

Factory Defaults

Series 4200/4400 SkyRouters are shipped with the following factory default settings

WAN Connection - Disabled

DHCP – Enabled

RS485 Communications – Enabled

Discrete input and output – Disabled (Discrete I/O and RS485 communications share common pins see section
2.3)

DNS Addressing – Acquire From Network

3.3

Connecting the Antenna

Antennas should be attached to the SMA style antenna connectors described in section 3. The antenna must be
connected before powering the unit on. ON the Z4200 the antenna connector to the right of the LAN LED is the primary
(transmit/receive) antenna and the connector to the left of the reset button is the secondary or diversity antenna.

3.4

Connecting to the Ethernet Port – Administrative Connection

To create a wired connection between a laptop and a SkyRouter connect the laptop using a standard Ethernet cable. For
a direct Ethernet connection between a PC connect to the Ethernet port using a standard or reverse Ethernet cable. The
PC should be set to obtain an IP address and DNS address automatically. For Windows PCs make the following settings
under the networking control panel

Figure 4 - Windows Configuration