Dynalco AF-900PC Air/Fuel Ratio Controller User Manual

Page 26

Advertising
background image

25

LEARN SCREEN

The Learn Screen (Fig. 10) displays the post-catalyst offset and valve learn tables
created during the MAP programming procedure. MAP pressure and post-catalyst
setpoint values are also shown on this screen. MAP programming may only be
initiated from the AF900PC front panel and will be discussed later in the manual.
Each new point programmed will be entered into the proper place on the table
according to the MAP pressure. The PC offset and valve pos % will change linearly
between points on the table. A point may be deleted from the table by clicking into
the En for that point, deleting the En with the backspace key, and entering DIS.
The PC offset and valve pos % for any point may be changed by deleting the old
value and entering a new value. The MAP values in the tables cannot be altered.




Learn Screen

Figure 10

Advertising