Step 10. plug in the power supply – EcoPure MW_MW30_7339971B User Manual

Page 15

Advertising
background image

15

Miracle Water Installation & Operation Manual

3. Fully open the main water supply valve. Observe steady flow from the opened faucets, with no

air bubbles.

4. EXACTLY as follows, place bypass valve(s) in “service”.

a. SINGLE BYPASS VALVE: SLOWLY, move the valve stem toward “service”, pausing several

times to allow the unit to pressurize slowly.

b. 3-VALVE BYPASS: Fully close the bypass valve and open the outlet valve. SLOWLY, open

the inlet valve, pausing several times to allow the unit to pressurize slowly.

5. After about three minutes, open a hot water faucet for about one minute, or until all air is

expelled, then close.

6. Close all cold water faucets and check your plumbing work for leaks.

Step 9. Add Water and Salt to the Salt Storage Tank

1. Using a container, add about one gallon of clean water into the salt storage tank.
2. Add salt pellets to the salt storage tank.
NOTE: See page 22 for additional information on salt.

Step 10. Plug In the Power Supply

NOTE: Check to be sure all leadwire connectors are secure on the back of the electronic

board.

CAUTION: Be sure all wiring is away from the valve gear and motor area, which rotates dur-

ing regenerations.

1. Plug the water softener’s power supply into a grounded household electrical outlet that is not

controlled by a switch and is approved by local codes.

Power

Supply

Advertising