Page 8

B.
Secure Relay in an upright position, as shown, to prevent moisture
from entering. Di-electric grease may be applied to prevent corrosion.
A.
Using ring terminals, attach red wire of the WH-1002 to the positive
battery terminal. Attach green wire to a clean ground, preferably the
negative battery terminal. Secure fuse block in a location protected
from outside elements. The use of a corrosion preventative on electri-
cal connections is recommended.
C.
Connect WE-1006 to the female lead of the WH-1002 coming off
the relay. Route the WH-1002 and WE-1006 along frame rail to the
factory lift pump. Completion of this step will be addressed in the
mounting step.
Step 1:
Install Electrical Harness
The installation of the electrical harness is done first, allowing power to be applied to the pump for
lubrication purposes later in the installation.