4. If you cannot identify the above fuses, remove all fuses in the fuse box.
5. Disconnect the negative (-) 12V battery cable (1).
Insulate the negative (-) battery cable terminal with
insulated tape.
6. Wait at least ten (10) minutes for complete discharge of the high voltage capacitor after the fuses
are pulled.
7. Perform the first response action.
To avoid unintended installation and risk of electrical shock and severe personal injury
or death, the rescuer should carry the fuses on his/her person and cover the fuse box with
insulated tape.
21