Troubleshooting

Fan does not turn when

electricity is connected

1. No electric power to heater.

2. Blades of fan in contact with heater

housing.

3. Fan blades bent.

4. Fan motor defective.

1. Check current at outlet. If voltage is correct,

inspect extension and power cords for cuts,
frays or breaks.

2. Check housing for damage. Be sure there

are no dents in the housing obstructing the
fan.

3. Straighten all fan blades.

4. Replace Motor Assembly.

Heater will not fire (ignite)

1. No spark at module.

2. Incorrect spark gap.

3. Corroded electrode.

1. Inspect module wire. Re-attach, or tighten if

loose. Inspect Spark module, and replace if
necessary. Inspect all other electrical
components.

2. Set plug gap to 0.16” (4mm).

3. Replace spark plug (Multi-Bracket

Assembly).

Heater stops running by

itself

1. Temperature inside heater is too high,

causing thermal switch to shut down
operation.

2. Damaged control valve.

3. Dust or debris accumulated in heater.

1. If heater input or output is restricted, the

inside temperature can become too hot.
Keep the areas in front and behind heater
clear of obstructions.

2. Replace control valve (Valve Assembly).

3. Clean inside of heater.

Symptom

Possible Cause(s)

Solution