Common option menu descriptions – CompuSTAR CM4000 User Manual

Page 4

Advertising
background image

OPTION GROUP 4

Feature

Default Setting - I

Optional Setting - II

Optional Setting - III

Optional Setting - IV

4-01

Aux 1 output

0.5sec

Latch

20 sec

Program

4-02

Aux 2 output

0.5sec

Latch

60 sec

Program

4-03

Aux 1 output Control

By Remote

Arm

Disarm

Panic

4-04

Aux 2 output Control

By Remote

Arm

Disarm

Panic

4-05

Secure Aux Output (1 and 2 Only)

On

Off

4-06

Auxiliary Input 1 – Green CN

Prewarn

Trigger

(-)Disarm

4-07

Auxiliary Input 2 – Green CN

Trigger

Prewarn

(-)Arm

4-08

Extended Accessory After Ign Shutoff

Off

10 sec

30 sec

Until Door Open

(1 min max)

4-09

Key Sense or Glow Plug input

Glow Plug Input

Key Sense Input

4-10

Trigger Start or Closed Loop

Alarm Trigger Input

Trigger Start input

Closed Loop

System Input

SPECIAL OPTION GROUP 1












Feature

Setting Value [seconds]

1

Diesel timer - DISL

3 ~ 99

2

AUX1 output time

1 ~ 100

3

AUX2 output time

1 ~ 100

4

AUX3 output time

1 ~ 100

5

AUX4 output time

1 ~ 100

6

AUX5 output time

1 ~ 100

7

AUX6 output time

1 ~ 100

8

AUX7 output time

1 ~ 100

SPECIAL OPTION GROUP 2









Feature

Setting Value

Programmable Output Connector

0 - Default Setting

1~19 – Optional Settings

1 POC

#1

(-) 2nd Parking Light

(Green/White)

2

POC #2

(-) 2nd Start (Red/Black)

3 POC

#3

(-) 2nd Ignition (Green)

4

POC #4

(-) 2nd Accessory

(White/Black)

5 POC

#5

(-) Status/GWR (Black)

6

POC #6

(-) Rearm Wire (Orange)

7 POC

#7

(-) Disarm Wire
(Orange/White)

8

POC #8

(-) Horn (White)

9 POC

#9

(-) Dome Light (Violet)

2nd Light - [1] 2nd Start - [2] 2nd Ignition - [3]

2nd Acc - [4] Status Out - [5] Rearm Out - [6]

Disarm Out - [7] Horn Out - [8] Dome Light - [9]

Aux1 Out - [10] Aux2 Out - [11] Defrost - [17]

GWA - [18] Status 2 For Manual Trans. - [19]









2-04 Trigger start - This option allows the control module to be used as a slave unit. This option determines whether the slave start wire on CN3 requires a single or double pulse to

activate the remote start. This can be used on vehicles where the user would like to keep the factory remote.

Common Option Menu Descriptions

1-01 Unlock before, Lock after remote starting - Doors will unlock to remote start and then relock once started. This is to disarm factory alarms on certain vehicles.

1-03 Driver’s priority unlock - The driver’s door must be isolated from the other doors. Use the Orange/Black CN4 as your negative 2

nd

Unlock output.


1-04 Double pulse unlock - Sends two negative (-) pulses on the blue unlock wire.

1-06 Reservation Lock (Manual Transmission) - Setting 1 allows the doors to lock when setting reservation. Setting 2 does NOT allow the doors to lock when setting reservation.
Setting 3 gives 10 seconds before setting reservation mode after closing the last door to allow the user to open another door.

1-09 Ignition controlled door locks – Default setting locks doors when foot on foot brake. Unlocks doors when key turned off or when e-brake set on manual transmissions. Tach or
alternator sensing mode must be used for this feature. You must also turn this feature on through the remote by tapping I + IV (2 Way remotes) or Lock + Key (1 Way remotes)

2-01 Tach Sensing Method – This option changes the method which is used to read tach on different vehicles. It adjusts for situations when there may be over cranking when remote
starting. This option can also be adjusted based on option 2-12 – Crank Time. Please see tech update from April 2008 on

www.compustar.com

for more info.


2-02 Turbo Timer - The e-brake must be connected to the control module. Available times are 1, 2, and 3 minutes. You must also turn on this feature through the remote by tapping
buttons III + IV.

2-03 Diesel Timer - Without setting this option you must find the vehicle’s wait to start wire. The default time for Setting 2 is 10 seconds. This can be increased or decreased only
with the Option Programmer OP500.