4 mounting with a hole for the laser – Baumer BA DenexMicro User Manual
Page 8
Advertising
User Manual DENEX MICRO
8/24
Baumer Electric AG
Version 2013-02, V1.6
www.baumer.com
Frauenfeld, Switzerland
4.4 Mounting with a hole for the laser
If there are mechanical parts 200-300 mm under the sensor that can cause reflections to
the detectors, the following mounting is recommended. It requires a small hole on the
conveyor, or a plate with a hole to screen off the reflection from the parts. The beam must
still be stopped with a dark plate or other material if there is any risk for a person to look
into the laser. Make sure that the laser goes through the hole properly. Normal back-edges
are not counted with this mounting.
Figure 4.4.1 Mounting with a hole to let the laser through.