N 141 – Baumer N 141 User Manual

Page 13

Advertising
background image

N 141

www.baumer.com

13

Turn display
This parameter turns the display by 180°.

0 = Off

Display readout with standard mounting, i.e. display above keypad

1 = On

Display readout with inverted mounting, i.e. display below keypad


Offset
Command „U“ is for programming the offset that is added to the current value and current target. This parameter
defines whether the offset is considered in the calculation.
Parameter 2 means optional manual offset alteration directly at the device itself. Press both softkeys at the same
time and proceed offset alteration by turning the shaft. Press the softkeys anew to quit. The bottom line shows
the unchanged current value again. The value alteration emerging from the shaft turn has been assigned to the
offset.

0 = Off

Offset disabled. The previous offset transmitted -if any- is neither added to current value nor
target

1 = SER

Offset enabled. Offset is added to the actual current value.
Offset alteration by serial interface

2 = S+K

Offset enabled. The offset is added to the actual current value.
Offset alteration either by serial interface or manually at the device.


Hide target
This parameter defines when to indicate the target in the upper line of the display.

0 = On

Ever indicate target if target ≠ current value

1 = Off

Ever indicate target, even if target = current value. Indicate also arrows if target ≠ current value.

2 = Ever

Ever hide both target and arrows.


4.3.2. Read /write parameter spindle tolerance and tolerance window, command „b“ (62h)

This command is for reading or writing the parameters tolerance compensation and tolerance window.

Example 1: Read parameter (tolerance compensation = 0,15; tolerance window = 0,25)

SOH

Adr

Cmd

EOT

CRC

Transmission

01h

20h

62h

04h

48h

SOH

Adr

Cmd Tolerance compensation=0,15

Tolerance window=0,25

EOT

CRC

Response

01h

20h

62h

30h

30h

31h

35h

30h

30h

32h

35h

04h

AAh



Example 2: Write parameter (tolerance compensation = 1,30; tolerance window = 5,00)

SOH

Adr

Cmd Tolerance compensation=1,30

Tolerance window=5,00

EOT

CRC

Transmission

01h

20h

62h

30h

31h

33h

30h

30h

35h

30h

30h

04h

20h

SOH

Adr

Cmd Tolerance compensation =1,30

Tolerance window=5,00

EOT

CRC

Response

01h

20h

62h

30h

31h

33h

30h

30h

35h

30h

30h

04h

20h


Advertising