7 object 0x6000 operating parameters, Object 0x6000 operating parameters, Able – Baumer ATD User Manual

Page 15: 14 s, Anager, Arameter, 15 o, Perating parameters

Advertising
background image

EtherCAT

15/42

Baumer Thalheim GmbH & Co. KG

2011-10-04/rnik

Eschwege, Germany

Encoders devices does not support dynamic object dictionary. Some of the values under this object are de-
pendent of the encoder operation mode (Sync or DC) and also dependent of the resolution. This means tim-
ing data is only true for:

1. Scaling Function Control disabled SFC=0
2. Distributed Clock mode operation

Sub
Index

Description

Value

01

Synchronization Type:
0: Free Run (not synchronized)
1: Sync – synchronized with SM3 Event
2: DC Sync0 – synchronized with Sync0 Event

0x0000

3

02

Cycle Time :
Free Run (Synchronization Type = 0) time between two local timer events
in ns.
Sync with SM2 (Synchronization Type = 1) Minimum time between two
SM2 events in ns.
DC Sync0 (Synchronization Type = 2) Sync0 Cycle Time (Register 0x9A0-
0x9A3) in ns.

0x0000 0000

4

03

Shift Time:
Time between related event and the associated action (inputs latched from
hardware) in ns.

TBD

04

Synchronization Types supported:
Bit 0: Free Run supported
Bit 1: Sync supported
Bit 2: DC Sync0 supported
Bit 5:4 No input shift supported

0x0007

05

Minimum cycle time supported of the slave (maximum duration time of the
local cycle) in ns.

0x**** ****

5

06

Calc and Copy Time

0x**** ****

Table 14 Sync Manager 3 Parameter List

2.4.1.7 Object 0x6000 Operating parameters

This object indicates the function for code sequence control.
Code sequence: The code sequence defines, whether increasing or decreasing position values are output, in
case the encoder shaft rotates clockwise or counter clockwise as seen from the point of view of the shaft.

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

-

-

-

-

-

-

-

-

-

-

-

-

-

1

-

cs

Table 15 Operating parameters

cs = Code Sequence

0 : CW
1 : CCW

sfc = Scaling Function Control

0 : disabled
1 : enabled

3

The value 0x0000 is the default value (Free Run mode)

4

Cycle Time data is only supported for DC mode.

5

Please check Chapter 6DC Timing.