Installation instructions - freestanding gas range, Check ignition of oven burners, Check ignition of surface burners – FRIGIDAIRE FFGF3053LS User Manual
Page 9
 
9
INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
Check ignition of oven burners.
The operation of oven igniters should be checked after 
range and supply line connectors have been carefully 
checked for leaks and range has been connected to 
electric power. Be sure all packing materials and litera-
ture are removed from oven. 
The oven burner is equipped with an electric control sys-
tem as well as an electric oven burner igniter. If your model 
is equipped with an upper oven burner, it will also have 
an electric burner igniter. These control systems require 
no adjustment. When the oven is set to operate, current 
will fl ow to the igniter. It will “glow” similar to a light bulb. 
When the igniter has reached a temperature suffi cient to 
ignite gas, the electrically controlled oven valve will open 
and fl ame will appear at the oven burner. There is a time 
lapse from 30 to 60 seconds after the thermostat is turned 
ON before the fl ame appears at the oven burner. When the 
oven reaches the set temperature, the glowing igniter will 
cycle off. The burner fl ame will turn off in 20 to 30 seconds 
after the igniter turns off. To maintain any set oven 
temperature, this cycle will continue as long as the oven 
control is set to operate.
To check oven burner ignition:
a. Set oven to Bake at 300ºF. See User’s Manual for 
operating instructions.
b. Within 60 seconds the oven burner should ignite.
Check for proper fl ame, and allow the burner to cycle 
once. Reset control to OFF.
c. If your model is equipped with a waist-high broiler,
set oven to Broil. See User’s Manual for operating 
instructions.
d. Within 60 seconds the broil burner should ignite.
Check for proper fl ame. Reset control to OFF.
Check ignition of surface
burners.
Operation of electric igniters should be checked after 
range and supply line connectors have been carefully 
checked for leaks and range has been connected to elec-
tric power.
a. To check for proper ignition, push in and turn a 
surface burner knob counterclockwise to the LITE 
position. You will hear the igniter sparking.
b. The surface burner should ignite when gas is available
to the burner. Purge air from supply lines by leaving 
knob in the LITE position until burner ignites. Each 
burner should light within four (4) seconds in normal 
operation after air has been purged from supply lines. 
c. Visually check that burner has a fl ame. Once the
burner ignites, the control knob should be turned out of 
the LITE position. 
d. Try each surface control knob separately until all
surface burners have been checked. Each burner 
location is equipped with a separate electrode.
 Adjust LOW setting of surface 
 burner 
valves
(linear
fl ow).
Test to verify if LOW setting should be adjusted:
a. Push in and turn control to LITE until burner ignites.
b. Push in and quickly turn knob to lowest position.
c. If burner goes out, reset control to OFF. 
d. Remove the surface burner control knob.
e. Insert a thin-bladed screwdriver into the hollow valve 
stem and engage the slotted screw inside. Flame size 
can be increased or decreased with the turn of the 
screw (see Fig. 17 amd Fig. 18).
f. Adjust
fl ame until you can quickly turn knob from
LITE to lowest position without extinguishing the 
fl ame. Flame should be as small as possible without 
extinguishing.
Note: Air mixture adjustments are not required on surface
burners.
Fig. 17
7
8
9
Burner fl ame size
5/8”
Cooktop
Fig. 18