Packaged terminal air conditioner (ptac), Rearward slope – FRIGIDAIRE FRP90ETT2R User Manual

Page 3

Advertising
background image

Front Panel

Chassis

Accessory

Wall Sleeve

Accessory

Outdoor Grille

Wall Sleeve

Adapter

PTAC - Heat Pump and Electric Heat models_Prod Specs

Rearward Slope

Outside Wall

1/4" Slope

Inside Wall

Specifications

subject to change.

Plug Type (NEMA)

6-20P

Product Dimensions

Height
Width
Depth
Max. Wall Thickness

Manufacturer

Wall Sleeve Part Number

General Electric

Amana
Trane

Friedrich

16"
42"
13-13/16"
13-13/16"

Metal Sleeve RAB71

Plastic Sleeve RAB77
Metal Sleeve WS900B
Metal Sleeve SLV149
T-Series Metal 11-1/2-in. Deep

Wall Sleeve
Standard-Depth Wall Sleeve

16 X 42 X 13-3/4-in. PXWS

Wall Cutout Dimensions

Height
Width

16-5/16"
42-3/16"

PTAC Specifications

•

Product Shipping Weight (approx.) – 128 Lbs.

•

An electrical supply with grounded three-prong receptacle is required.

The power supply circuit must be installed in accordance with current

edition of National Electrical Code (ANSI/NFPA 70)

and local codes & ordinances.

•

Voltage Rating – 230V / 208V / 60 Hz / 20 Amps

•

Amps @ 230/208V Volts =

(Cool) 3.7 / 3.9 Amps / (Electric Heater) 13.2 / 12.2 Amps

•

Always consult local and national electric codes.

•

Recommended Circuit Breaker – 20 Amps

•

Unit equipped with 230/208V 3-wire power supply cord, NEMA plug

type 6-20P, approximately 66" long.

•

In order for condensate water to drain properly inside the unit, the

sleeve must be installed properly: Level from right to left with a slight

1/4" rearward pitch from the indoor side to the outdoor side as shown in

the illustration above. Refer to the Installation Instructions on the web.

•

The drain kit listed on the Frigidaire® PTAC Accessories page can

be used for an internal or external drain. This applies to new and

replacement installation.

New Installation

•

For new installation, Frigidaire® PTAC Sleeves are available and

recommended for proper installation. See accessories pages for

sleeve options.*

•

Standard PTAC installation requires 13-13/16" maximum wall thickness,

unless a wall sleeve is used.

•

If the PTAC unit protrudes more than 4", then it is suggested that it be

installed with a subbase. See accessories pages for subbase options.

Replacement Installation

•

When replacing existing PTAC with new unit, refer to Product

Installation Guide on web to identify existing wall-sleeve manufacturer

and size compatibility. If proper installation and slope are suspect,

then correct installation of Frigidaire® PTAC Sleeve options

recommended.

•

For any sleeve retrofit application, be sure that the foam seals

(factory-installed on the tube sheets) provide a good seal between

the grille and the outdoor coil tube sheets. These foam seals provide

a barrier that stops air from the inside mixing with air on the outside

(known as air recirculation).

•

Using Frigidaire® wall sleeve with Non-Frigidaire grille requires

installation of an Accessory Baffle Kit, which ensures a good seal

between the unit and exterior grille to prevent air recirculation. Air

recirculation is a large contributor to performance loss and premature

damage to major components.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

*See Frigidaire® PTAC accessories pages attached for optional accessories.

USA

•

10200 David Taylor Drive

•

Charlotte, NC 28262

•

1-866-942-1567

•

frigidaire.com

CANADA

•

5855 Terry Fox Way

•

Mississauga, ON L5V 3E4

•

1-866-942-1567

•

frigidaire.ca

FRP90ETT2R 08/11

© 2011 Electrolux Home Products, Inc.

Printed in the U.S.A.

Packaged Terminal Air Conditioner (PTAC)

FRP90ETT2R

Air Conditioner / Electric Heater 