Specifications

subject to change.

Overhead Hoods

FHWC3025M S / W/ B

30" Under-Cabinet

30" Under-Cabinet Vent Hood (recirculating model)

FHWC3025M

Frigidaire Baseline

Under-Cabinet Hood Specifications

Product Shipping Weight (Approx.) – 18 Lbs.

Under-Cabinet Installation – can be ducted vertically or horizontally.

Ventilation system can exhaust air outside, either vertically

through roof or horizontally through wall. (Refer to Ducting Option

Specifications for outside ventilation.). If ducting outside is not

possible, the system can be alternately set to recirculate air inside,

requiring use of recirculating kit, included with hood.

Sones Rating – 5.8

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = .72 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire

service with a separate ground wire. Appliance must be grounded for

safe operation.)

Amps @ 120 Volts = 1.06 Amps

Always consult local and national electric codes. Check local building

codes for installation requirements, as they may vary per locale.

Makeup air systems may be required by local building codes

when using ventilation systems greater than specified CFM of air

movement. Specified CFM varies per locale.

Connect vent hood with copper wire only. (For installation pre-wired

with aluminum wiring, refer to Product Installation Guide on web for

correct wiring procedure.)

Locate vent hood away from strong draft areas, such as windows,

doors or strong heating vents.

Minimum 18" - 24" installation height allowed from bottom of hood

canopy to cooking surface; minimum 66" height suggested from

top of hood to floor.

When installing vent hood under cabinets with recessed bottoms,

two 2"-wide filler strips required with length and thickness

determined by recess dimensions.

Ducting Option Specifications

Vent system MUST terminate outside through roof or wall; do NOT

terminate into attic or other enclosed area.

Exhaust Duct Required – 3-1/4" x 10" rectangular with 35' maximum

vent length or 7" round with 50' maximum vent length. Refer

to Product Installation Guide on web for calculations needed to

determine total duct length.

Installation of 7" Round Duct requires use of optional 7" Round

Transition Duct (PN # 5304487139) and can only be vented vertically.

To provide efficient performance, length of vent system and number

of elbows should be kept to minimum. Flexible vent greatly reduces

performance and is NOT recommended.

Use 3-1/4" x 10" rectangular metal vent only – rigid metal vent

recommended; plastic or metal foil vent NOT recommended.

For cold weather installation, additional backdraft damper and thermal

break should be installed. Thermal break will minimize conduction of

outside temperatures as part of the vent system with damper on cold

air side of break, as close as possible to where vent system enters

heated portion of house.

Refer to Product Installation Guide on web for detailed vent system

preparation instructions.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Optional Accessories

7" Round Transition Duct – (PN # 5304487139).

Charcoal Filter – (PN # 5304486302).