30" electric range installation instructions – FRIGIDAIRE FGEF300DNB User Manual

Page 6

Advertising
background image

6

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS

Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box

If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use fl exible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief at each end
of the cable. At the appliance end, the cable goes
through the Direct Connection Hole (see Figure 8) on
the Cord Mounting Plate. Wire sizes (copper wire only)
and connections must conform to the rating of the
appliance.

Where local codes permit connecting the
appliance-grounding conductor to the neutral
(white) wire (see Figure 9):
1. Be sure that no power is supplied on the cable from

residence.

2. Follow instructions on previous page for Four

Conductor Wire Connection to Range (Fig. 8).

3. In the circuit breaker, fuse box or junction box (Fig. 9):
a) Connect the green (or bare copper) wire, the white

appliance cable wire, and the neutral (white) wire
together.

b) Connect the 2 black wires together.
c) Connect the 2 red wires together.

Figure 9

3-Wire (Grounded Neutral) Electrical System

(Example: Junction Box)

Cable from Residence

Junction

Box

White Wire

U.L.-listed Conduit
Connector (or CSA
listed)

Cable from

Appliance

Green
(or Bare Copper)
Wire

Red
Wires

Neutral

(white) Wire

Black
Wires

NOTE: Be sure to remove the
supplied grounding strap.

Where local codes DO NOT permit connecting
the appliance-grounding conductor to the neutral
(white) wire, or if connecting to 4-wire electrical
system (see Figure 10):
1. Be sure that no power is supplied on the cable from

residence.

2. Follow instructions on previous page for Four

Conductor Wire Connection to Range (Fig. 8).

3. In the circuit breaker, fuse box or junction box (Fig. 10):
a) Connect the white appliance cable wire to the neutral

(white) wire.

b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding wire

to the grounding wire of the circuit breaker, fuse box
or junction box.

NOTE: Be sure to remove the
supplied grounding strap.

U.L.-listed Conduit
Connector (or CSA
listed)

Figure 10

– 4-Wire Electrical System

(Example: Junction Box)

Cable from Residence

Black
Wires

Junction

Box

White Wire

Cable from

Appliance

Green (or Bare
Copper) Wire

Red
Wires

White Wire

Green (or Bare
Copper) Wire

6. Checking Operation

Refer to the Use and Care Guide for operation.

CAUTION

Do not touch cooktop glass or elements.

They may be hot enough to burn you.

Before You Call for Service

Read the Before You Call for Service Checklist and
operating instructions in your Use and Care Guide.
It may save you time and expense. The list includes
common occurrences that are not the result of
defective workmanship or materials in this appliance.

Advertising
This manual is related to the following products: