30" GAS SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

(Models with Sealed Top Burners)

Assemble the flexible connector from the gas supply pipe
to the pressure regulator in the following order:
1. Manual shutoff valve (not included)
2. 1/2" nipple (not included)
3. 1/2" flare union adapter (not included)
4. Flexible connector (not included)
5. 1/2" flare union adapter (not included)
6. 1/2" nipple (not included)
7. Pressure regulator (included)

The supply line must be equipped with an approved
manual shutoff valve. This valve should be located in
the same room as the range and should be in a location
that allows ease of opening and closing. Do not block
access to the shutoff valve. The valve is for turning on or
shutting off gas to the appliance.
Once regulator is in place, open the shutoff valve in the
gas supply line. Wait a few minutes for gas to move
through the gas line.

Check for leaks. After connecting the range to the gas
supply, check the system for leaks with a manometer. If
a manometer is not available, turn on the gas supply and
use a liquid leak detector (or soap and water) at all joints
and connections to check for leaks.

Do not use a flame to check for leaks

from gas connections. Checking for leaks with a flame
may result in a fire or explosion.

Tighten all connections as necessary to prevent gas
leakage in the range or supply line.

Disconnect this range and its individual shutoff
valve
from the gas supply piping system during any
pressure testing of the system at test pressures greater
than 1/2 psig (3.5 kPa or 14"(35,56 cm) water column).

Isolate the range from the gas supply piping system
by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa or 14"
water column).

Figure 5

Shutoff Valve -

Open position

to appliance

to gas suppl

y line

All connections must be wrench-tightened

Figure 4

Flare

Union

Flare

Union

GAS FLOW

Manual

Shutoff

Valve

Pressure

Regulator

On

Off

Flexible

Connector

Access

Cap

Nipple

Nipple

Connection to Pressure Regulator

The regulator is already installed on the appliance.

Do not make the connection too tight.

The regulator is die cast. Overtightening may crack the
regulator resulting in a gas leak and possible fire or
explosion.

Figure 3

3

Seal the openings

Seal any openings in the wall behind the range and
in the floor under the range after gas supply line is
installed.

4

Connect the range to the gas

supply

Important:

Remove all packing material and literature

from range before connecting gas and electrical supply.
To prevent leaks, put pipe joint sealant on all external
pipe threads.

PRESSURE REGULATOR

LOCATION

Your regulator is in
location shown below.

Do

not allow regulator to
rotate on pipe when
tightening fittings.

Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible
connectors are used, be certain connectors are not
kinked.

Advertising