Before you call, 12 problem cause correction – FRIGIDAIRE FGVU17F8QT User Manual

Page 12

Advertising
background image

12

PROBLEM

CAUSE

CORRECTION

Longer sound

levels when

compressor

comes on.

• Appliance operates at higher

pressures during the start of

the ON cycle.

• This is normal. Sound will level off or

disappear as appliance continues to run.

Popping or

cracking sound

when compres-

sor comes on.

• Metal parts undergo

expansion and contraction, as

in hot water pipes.

• This is normal. Sound will level off or

disappear as appliance continues to run.

Bubbling

or gurgling

sound, like

water boiling.

• Refrigerant (used to cool

the appliance) is circulating

throughout the system.

• This is normal.

Vibrating or

rattling noise.

• Appliance is not level. It rocks

on the floor when it is

moved slightly.

• Floor is uneven or weak.

• Appliance is touching

the wall.

• Level the unit. Refer to ”Leveling” in the First

Steps Section.

• Ensure floor can adequately support appliance.

Level the appliance by putting wood or metal

shims under part of the freezer.

• Re-level the appliance or move appliance

slightly. Refer to “Leveling” in the First

Steps Section.

Alarm is

sounding

from the con-

trol panel

• Look on the control panel to

determine which indicator

light is on (High Temp, Power

Fail, or Door Ajar).

• Press the “set” button to acknowledge the

alarm or close the door if the door ajar

indicator is shown.

WATER/MOISTURE/FROST INSIDE APPLIANCE
Moisture

forms on in-

side appliance

walls.

• Weather is hot and humid.
• Door is opened too often or

too long.

• This is normal.
• Open door less often.

ODOR IN APPLIANCE
Odor in appli-

ance.

• Interior needs to be cleaned.

• Foods with strong odors are

in the appliance.

• Clean interior with sponge, warm water, and

baking soda.

• Cover the food tightly.

LIGHTING PROBLEMS
Light bulb is

not on.

• No electric current is reaching

the appliance

• Control is in Sabath mode (Sb

is displayed on control)

• See “APPLIANCE DOES NOT RUN”.

• Depress TEMP MODE key and CONTROL LOCK

key for 3 seconds.

BEFORE YOU CALL