Drop-in gas cooktops (version 1), Professional / gallery / baseline, Drop-in cooktop – FRIGIDAIRE FFGC3603LW User Manual

Page 3: Callouts must be charted per individual model)

Advertising
background image

Accessories information available

on the web at

frigidaire.com

Drop-In Gas Cooktops (Version 1)

(Callouts MUST be charted per individual model).

Professional / Gallery / Baseline

BASED ON INSTALL GUIDE

VERBIAGE (VERSION 1)
(G)
min. between rear

edge of cooktop and adjacent

combustible surface

(or backsplash)

USA

•

10200 David Taylor Drive

•

Charlotte, NC 28262

•

1-800-FRIGIDAIRE

•

frigidaire.com

CANADA

•

5855 Terry Fox Way

•

Mississauga, ON L5V 3E4

•

1-800-265-8352

•

frigidaire.ca

FFGC3603L 11/13

© 2013 Electrolux Home Products, Inc.

Specifications

subject to change.

Drop-In Cooktop

FFGC3603LW

36" Gas

Drop-In Cooktop Specifications

•

Product Shipping Weight (approx.) – 30 Lbs.

•

Voltage Rating – 120V / 60 Hz / 15 Amps

•

For use on adequately wired 120V, dedicated circuit having 2-wire

service with a separate ground wire. Appliance must be grounded

for safe operation.

•

Amps @ 120 Volts = 1.0 Amps

•

Always consult local and national electric and gas codes.

•

Cooktop cutout height includes clearance needed beneath cooktop

to allow for gas supply connection. Recommended location for

grounded 120V outlet is on rear wall in an 8"-wide by 10"-high area,

positioned 22" above floor surface and 9-1/8" from right side of

cooktop centerline. Access to underside of cooktop and junction box

must be provided for inspection and service.

•

Cooktop ships with 3/4" factory regulator.

•

LP Gas conversion kit supplied.

•

Overhead cabinetry should not exceed a 13" maximum depth.

•

Absolute minimum horizontal distance between overhead cabinets

installed to either side of appliance must be no less than 36".

•

Allow 30" minimum clearance between top of cooktop platform and

bottom of unprotected wood or metal overhead cabinet.

•

Allow 2-1/2" minimum distance between rear edge of cooktop and

adjacent combustible surface (or backsplash).

•

Allow 1" minimum required clearance from left edge of cooktop to

adjacent combustible surface and 1" minimum from right edge of

cooktop to adjacent combustible surface.

•

To reduce risk of fire when using overhead cabinetry, install range

hood that projects horizontally a recommended minimum of 5"

beyond bottom of cabinets.

•

Gas Drop-In Cooktop model FFGC3603L is NOT approved to be used

over any Frigidaire® Single Wall Oven.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Optional Accessories

•

Granite Countertop Installation Kit – (PN # 903103-9010).

Product Dimensions

Required Clearances

A - Width

B - Depth

C - Height

G (min.)

H (min.)

I (min.)

J (min.)

36"

18-5/8"

3-1/4"

2-1/2"

1"

1"

–

Product Cutout Dimensions

K - Cabinet Opening Width

(min.)

Utility Connection Locations

D - Width (min. - max.)

E - Depth (min. - max.)

F - Height (min.)*

Power Supply

Gas Supply

34-1/4" - 34-3/8"

16-5/8" - 16-3/4"

8-1/4"

36"

Center Front

Center Front

Advertising