30" electric drop-in range frig baseline, Drop-in ranges – FRIGIDAIRE FFED3015PB User Manual

Page 3

Advertising
background image

Specifications

subject to change.

30" Electric Drop-In Range

Frig Baseline

USA

•

10200 David Taylor Drive

•

Charlotte, NC 28262

•

1-800-FRIGIDAIRE

•

frigidaire.com

CANADA

•

5855 Terry Fox Way

•

Mississauga, ON L5V 3E4

•

1-800-265-8352

•

frigidaire.ca

FFED3015P 10/14

© 2014 Electrolux Home Products, Inc.

Drop-In Range Specifications

•

Product Shipping Weight (approx.) – 170 Lbs.

•

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt,

60 Hertz, fused on both sides of line with ground. (If local code

permits, range may be connected by hard-wiring or by means

of power supply cord kit.)

•

Connected Load (kW Rating) @ 240 / 208 Volts = 11.6 / 8.7 kW

•

Amps @ 240 / 208 Volts = 48.3 /41.8 Amps

•

Recommended Circuit Breaker – 50 Amps (40 Amps minimum)

•

Always consult local and national electric codes.

•

Make sure wall coverings around range can withstand heat generated

by range.

•

Linoleum or any other synthetic floor covering located beneath range,

must be capable of withstanding minimum heat of 90° F above room

temperature without shrinking, warping or discoloring. Insulating pad

or 1/4"-thick plywood required between range and a carpeted floor.

•

When installing optional Backguard Kit, cutout depth of 21-3/4"

minimum / 22-1/8" maximum needs increased to 24".

•

Overhead cabinetry should not exceed a 13" maximum depth.

•

Absolute minimum horizontal distance between overhead cabinets

installed to either side of appliance must be no less than maximum

width of appliance.

•

Allow 24" minimum clearance between rangetop and bottom of cabinet

when bottom of wood or metal cabinet is protected by not less than

1/4" flame-retardant millboard covered with not less than No. 28 MSG

sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.

Allow 30" minimum clearance when cabinet is unprotected.

•

To reduce risk of fire when using overhead cabinetry, install

range hood that projects horizontally a recommended minimum

of 5" beyond bottom of cabinets.

Countertop Preparation

Rangetop’s side flanges overlap countertop cutout edges – for detailed

preparation instructions, refer to product installation guide on the web.

•

Flat Square-Finish Countertops – require no preparation since

rangetop’s flange lays directly on countertop edge.

•

Formed Front-Edged Countertops – require front molded edge to

be shaved flat 3/4" from each front corner of opening.

•

Tile Countertops – may need trim cut back 3/4" from each front

corner of opening and /or rounded edge flattened.

•

For existing cutout width greater than 30-1/16" reduce the 3/4"

overlap dimension; for cutout width of 29", replace actual side

trim panels with smaller side trim panels, available with optional

Side Trim Kit (refer to detailed kit installation instructions).

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Optional Accessories

•

Rear Filler Kit: White – (PN # 901193-9011),

Black – (PN # 901193-9010).

•

Backguard Kit: White – (PN # 903046-9011),

Black – (PN # 903046-9010).

•

Side Trim Kit: White – (PN # 903076-9011),

Black – (PN # 903076-9010).

•

Bottom Trim Kit: White – (PN # 903068-9011),

Black – (PN # 903068-9010).

Drop-In Ranges

FFED3015P W / B

30" Electric