Freestanding Range Specifications

•

Product Shipping Weight (approx.) – 265 Lbs.

•

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt,

60 Hertz, fused on both sides of line with ground. (If local code

permits, range may be connected by hard-wiring or by means

of power supply cord kit.)

•

Connected Load (kW Rating) @ 240 / 208 Volts = 4.5 / 3.4 kW

•

Amps @ 240 / 208 Volts = 19.0 / 16.0 Amps

•

Recommended Circuit Breaker – 30 Amps

•

Always consult local and national electric and gas codes.

•

Make sure wall coverings around range can withstand heat generated

by range.

•

Linoleum or any other synthetic floor covering located beneath range,

must be capable of withstanding minimum heat of 90° F above room

temperature without shrinking, warping or discoloring. Insulating pad

or 1/4"-thick plywood required between range and a carpeted floor.

•

Do not obstruct flow of combustion air at oven vent nor around base

or beneath lower front panel of range. Range requires fresh air for

proper burner combustion.

•

Range ships with 1/2" NPT factory regulator.

•

LP Gas Conversion Kit supplied.

•

Gas supply piping can be routed through side wall of right cabinet.

Right side cabinet is ideal location for main shutoff valve.

•

Overhead cabinetry should not exceed a 13" maximum depth.

•

Absolute minimum horizontal distance between overhead cabinets

installed to either side of appliance must be no less than maximum

width of appliance.

•

Allow 24" minimum clearance between rangetop and bottom of

cabinet when bottom of wood or metal cabinet is protected by

not less than 1/4" flame-retardant millboard covered with not less

than No. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum

or 0.020" copper. Allow 30" minimum clearance when cabinet is

unprotected.

•

To reduce risk of fire when using overhead cabinetry, install

range hood that projects horizontally a recommended minimum

of 5" beyond bottom of cabinets.

•

Minimum 2-1/2" clearance required from edge of rangetop to nearest

combustible wall on either side of range above 36" height.

•

Range can be installed flush to wall with 0" minimum rear clearance.

•

For installation against left side wall that extends to or beyond

range's side panel, allow 2-3/4" minimum clearance to allow

auxiliary oven door to open.

•

Follow all dimension requirements provided to prevent property

damage, potential fire hazard, and incorrect countertop and

cabinet cuts.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Freestanding Range