Freestanding Range Specifications

Product Shipping Weight (approx.) – 265 Lbs.

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt,

60 Hertz, fused on both sides of line with ground. (If local code

permits, range may be connected by hard-wiring or by means

of power supply cord kit.)

Connected Load (kW Rating) @ 240 / 208 Volts = 4.5 / 3.4 kW

Amps @ 240 / 208 Volts = 19.0 / 16.0 Amps

Recommended Circuit Breaker – 30 Amps

Always consult local and national electric and gas codes.

Make sure wall coverings around range can withstand heat generated

by range.

Linoleum or any other synthetic floor covering located beneath range,

must be capable of withstanding minimum heat of 90° F above room

temperature without shrinking, warping or discoloring. Insulating pad

or 1/4"-thick plywood required between range and a carpeted floor.

Do not obstruct flow of combustion air at oven vent nor around base

or beneath lower front panel of range. Range requires fresh air for

proper burner combustion.

Range ships with 1/2" NPT factory regulator.

LP Gas Conversion Kit supplied.

Gas supply piping can be routed through side wall of right cabinet.

Right side cabinet is ideal location for main shutoff valve.

Overhead cabinetry should not exceed a 13" maximum depth.

Absolute minimum horizontal distance between overhead cabinets

installed to either side of appliance must be no less than maximum

width of appliance.

Allow 24" minimum clearance between rangetop and bottom of

cabinet when bottom of wood or metal cabinet is protected by

not less than 1/4" flame-retardant millboard covered with not less

than No. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum

or 0.020" copper. Allow 30" minimum clearance when cabinet is

unprotected.

To reduce risk of fire when using overhead cabinetry, install

range hood that projects horizontally a recommended minimum

of 5" beyond bottom of cabinets.

Minimum 2-1/2" clearance required from edge of rangetop to nearest

combustible wall on either side of range above 36" height.

Range can be installed flush to wall with 0" minimum rear clearance.

For installation against left side wall that extends to or beyond

range's side panel, allow 2-3/4" minimum clearance to allow

auxiliary oven door to open.

Follow all dimension requirements provided to prevent property

damage, potential fire hazard, and incorrect countertop and

cabinet cuts.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.