Connect second Operator to Control
Board (Model Ga420D Only)

• Before digging, contact local underground utility

locating companies.

• Trench across driveway to bury the extension

cable.

• Use PVC conduit to prevent damage to cables.

• Insert extension cable through watertight

connector nut and through an available watertight
connector mounted in the control box.

• Extend cable and wires to GATE 2 connector and

connect as shown.

• Secure extension cable to control box using

watertight connector nut.

To AVOID damaging gas, power or other underground utility
lines, contact underground utility locating companies BEFORE
digging.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

CAUTION

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

Wiring 26

1

L1

R1

R2

Z1

K5

K6

K2

F3

10A 32V

D1Ø

P1

F2

F6

D4

D2

R9

C64

JMPR1

U4

FORCE

TIMER TO

CLOSE

OFF MAX

R35

D9

Z3

Z4

U3

D1

D27

F5

C11

C13

C12

D15

C2

R4

R1Ø1

R1ØØ

R9Ø

Q9

K1

R196

Q22

D8

K3

K4

D21

D22

C4

ACCESSORY

OVLD

D6

JMPR2

MOV1

MOV2

DB1

U2

Z12

24 VAC/
SOLAR
INPUT

GATE 2

ACCESSORY

POWER

MAGLOCK

ALARM

GATE 1

C

C

NC

NO

NO

GRN

WHT

YEL

BLU

RED

BRN

GRN

WHT

YEL

BLU

RED

BRN

F4

10A 32V

F7

24V

TIMER

RUNNING

GATE 2

SET

OPEN
LIMIT

SET

CLOSE

LIMIT

LEARN
LIMITS

DIAGNOSTIC

GATE 1

J4

LEARN

XMITTER

MAGLOCK

ON OFF

Z22

R91

CLOSE
EDGE

R94

R92

R93

L1

R1

R2

Z1

K5

K6

K2

F3

10A 32V

D1Ø

OPEN EDGE/

PHO T O

OPEN
PHO T O

CLOSE
PHO T O

R227

R2Ø7

Z2 Ø

R223

P1

Z9

Z8

F2

F6

D4

D2

R9

C64

JMPR1

R224

U4

CONTROL

INPUTS

FORCE

TIMER TO

CLOSE

OFF MAX

OPEN

SINGLE BUTTON

RESET

STOP

SHADOW

INTERRUPT

CHGR
OVLD

COM

COM

COM

FUSE
OPEN

LOOP

INPUTS

POWER

BATT 1

BATT 2

F1 20A 32V

R35

D9

Z3

Z4

U3

D1

D27

F5

C11

C13

C12

D15

C2

R4

R1Ø1

R1ØØ

R9Ø

Q9

K1

R196

Q22

D8

K3

K4

D21

D22

C4

ACCESSORY

OVLD

D6

JMPR2

MOV1

MOV2

DB1

U2

Z12

24 VAC/
SOLAR
INPUT

GATE 2

ACCESSORY

POWER

MAGLOCK

ALARM

GATE 1

C

C

NC

NO

NO

GRN

WHT

YEL

BLU

RED

BRN

GRN

WHT

YEL

BLU

RED

BRN

F4

10A 32V

F7

24V

COM
OVLD

TIMER

RUNNING

GATE 2

SET

OPEN
LIMIT

SET

CLOSE

LIMIT

LEARN
LIMITS

DIAGNOSTIC

GATE 1

J4

LEARN

XMITTER

MAGLOCK

ON OFF

D15

C2

R4

R9Ø

R196

24 VAC/

SOLAR

INPUT

GATE 2

ACCESSORY

POWER

GRN

WHT

YEL

BLU

RED

BRN

10A 32V

24V

Mov

ing

Gate Can

Ca

use

Inju

ry o

r Death

KEE

P CL

EAR!

Gate

may

mo

ve a

t any

tim

e wit

hout

pri

or w

arn

ing.

Do

not

let c

hild

ren

ope

rate

the

gat

e o

r

play

in the

gat

e ar

ea.

This

entr

ance

is f

or vehic

les o

nly

Pedest

rians

mu

st use

sepa

rate

ent

rance

Terminal blocks
can be removed
to simplify wiring.

PVC conduit (not provided) to protect the
power cable and low voltage wire from lawn
mowers and string trimmers.

Control Box

Gate Operator (Gate 2)

Gate Operator (Gate 1)

Operator
Cable

PVC Conduit

Junction Box

Extension Cable

Extension Cable

PVC conduit at
least 18" below
ground level
(grade)

Brown

Green

White

Yellow

Blue

Red

Advertising
This manual is related to the following products: