2 connect batteries, Connect batteries, 31 wiring – Chamberlain RESIDENTIAL GATE OPERATOR GA420D User Manual

Page 31

Advertising
background image

31

Wiring

Connect Batteries

The batteries are charged in circuit by using the transformer (provided).

Locate the two white battery plugs on the left-hand side of the control box. Connect the plug from the battery to
connector on the control board.

NOTES: Batteries will degrade over time depending on temperature and usage. For best performance, the batteries
should be changed every 3 years.
Batteries do not perform well in extremely cold temperatures. For locations where the temperatures are below -20°C
(-4°F) contact technical support.

To reduce the risk of FIRE or INJURY to persons use ONLY
Chamberlain part 922GA for replacement batteries.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

CAUTION

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

18

18

R93

R93

L1

L1

D42

D42

K2K2

D1

D1Ø

Z22Z22

P1P1

F2F2

MO

V1

MO

V1

D1D1

Q12Q12

U4

U4

OFF

OFF

MAX

MAX

OPEN

OPEN

SINGLE BUTTON

SINGLE BUTTON

RESET

RESET

STOP

STOP

CHGR

CHGR
OVLD

OVLD

COM

COM

COM

COM

D129

D129

Z4

Z4

U

3

U3

D2

D2

D44

D44

C11C11

C13

C13

C12C12

D16D16

F9F9

R1

R1Ø1

R1

R1ШШ

ШШ

K1K1

Q22

Q22

F3

F3

K3K3

K4K4

R196

R196

F1

F1

Z12

Z12

GATE 2

GATE 2

GATE 1

GATE 1

MAGR

MAGR

SOL

SOL

GR

GR

WH

WH

YL

YL

BL

BL

RD

RD

BR

BR

GR

GR

WH

WH

YL

YL

BL

BL

RD

RD

BR

BR

F7

F7

24V

24V

CTRL

CTRL
OVLD

OVLD

TIMER

TIMER

RUNNING

RUNNING

GATE 2

GATE 2

SET

SET

OPEN

OPEN

LIMIT

LIMIT

SET

SET

CLOSE

CLOSE

LIMIT

LIMIT

LEARN

LEARN
LIMITS

LIMITS

GATE 1

GATE 1

LEARN

LEARN

XMITTER

XMITTER

LOCK /

LOCK /

ON

ON

OFF

OFF

C69C69

OFF

OFF

MAX

MAX

J2J2
Ø

PWR

PWR

AC PWR

AC PWR
/SOLAR

/SOLAR

D8D8

D4D4

R9R9

R329R32

9

R27R27

MO

V2

MO

V2

R4R4

C2C2

BIPART DELAY

BIPART DELAY

LOCK

LOCK

GND

GND

Z1

Z1

R1

R1

R2

R2

K5K5

F12

F12

Q9Q9

R9

R9Ø

F8

F8

Q6Q6

Q1Q1

J19J19

R182

R182

C1

C1Ш1

Ш1

C75

C75

C73

C73

C72

C72

C71

C71

C7

C7Ø

C66

C66

C65

C65

C68C68

C33C33

F11F11

R186R18

6

R42

R42Ø
R423

R423

J24 J23 3J24 J

23 3

Ø

A 32VA 32V

3 3

Ø

A 32VA 32V

J21J21

3030

3030

C64C64

R22

R22

U2

U2

J18J18

K6

K6

JU1JU1

JU1JU1

JU2

JU2

DB1

DB1

D36

D36

R184

R184

Battery Connectors

Battery Connection (GA420D Only)

Battery Connection (GA400D Only)

Battery Connectors

Control Board

Board Connectors

Board Connectors

2

OR

Advertising
This manual is related to the following products: