Release Pin

Gate Bracket

37

Operation and Maintenance

Manual Release

In case of a power failure, the operator can be disengaged from the gate. Follow the directions below to disconnect and
reconnect the operator to the gate.

Release

1.

Remove the hairpin clip and release pin that secures the gate bracket to the gate.

2.

Move operator away from gate and out of the way of gate travel.

If a gate lock (automatic or manual) is used; disengage the lock.

Engage

1.

Align the hole in the arm with the hole in the gate bracket.

2.

Insert release pin and secure with hairpin clip.

Check for proper operation

Check and operate

Inspect for wear or damage

Check all for proper operation

Inspect all wire connections

Check for tightness

Replace

Inspect for wear or damage

Entrapment
Protection Systems

Manual Release

Gate

Accessories

Electrical

Mounting Hardware

Batteries

Total Unit

C H E C K A T L E A S T O N C E E V E R Y

NOTES:

1. Disconnect power before servicing.

2. Severe or high cycle usage will require more frequent

maintenance checks.

3. Inspection and service should always be performed

anytime a malfunction is observed or suspected.

4. When servicing, please do some “house cleaning” of the

operator and the area around the operator. Pick up any
debris in the area. Clean the operator as needed.

5. It is suggested that while at the site voltage readings be

taken at the operator. Using a Digital Voltmeter, verify
that the incoming voltage to the operator it is within ten
percent of the operator’s rating.

6. See page 34 for instructions on how to check gate force

and sensitivity adjustments.