30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

(Models with an Electric Oven and a Gas Cooktop)

9

Min.

Cutout

Width

Formed or tile countertop

trimmed ¾" (1,9 cm) back at

front corners of countertop

opening.

Figure 7

6

Gas Supply – Installation

When shipped from the factory, this unit is designed

to operate on 4" (10,16 cm) water column (1,0 kPa)

Natural gas manifold pressure. A convertible pressure

regulator is connected to the range manifold and

MUST be connected in series with the gas supply line.

To access the regulator, remove the drawer.
For proper operation, the maximum inlet pressure to

the regulator should be no more than 14" (35,6 cm) of

water column pressure (3,5 kPa).
The inlet pressure to the regulator must be at least

1" (0,25 kPa) greater than the regulator manifold

pressure setting. The regulator is set for 4" (10,2 cm)

water column (1,0 kPa) Natural gas manifold pressure;

the inlet pressure must be at least 5" (12,7 cm) water

column (1,25 kPa) Natural gas. For LP/Propane gas, the

regulator must be set for 10" (25,4 cm) water column

(2,5 kPa) manifold pressure; the inlet pressure must be

at least 11" (27,9 cm) water column (2,75 kPa).
The supply line should be equipped with an approved

shutoff valve (see Figure 11). This valve should be

located in the same room as the range and should be

in a location that allows ease of opening and closing.

Do not block access to the shutoff valve. The valve is

for turning on or shutting off gas to the appliance.
Open the shutoff valve in the gas supply line. Wait a

few minutes for gas to move through the gas line.
The gas supply between the shutoff valve and the

regulator may be connected by rigid piping or by

A.G.A./C.G.A.-approved flexible metallic union-

connected piping where local codes permit use.
The gas supply piping can be through the back wall

(Figure 8, zone 1) or through the floor (Figure 8,

zone 2):

Zone 1 - Through the Back Wall (7" (17,8 cm) X 6"

(15,2 cm)) - The best place to have your gas line in is

between 1" (2,5 cm) and 8" (20,3 cm) from the floor and

within 3" (7,6 cm) from the center line.

Zone 2 - Through the Floor (~2" (5,1 cm) X 24" (61

cm)) - The gas line can also come through the floor

within 12" (30,5 cm) from the center line against the

back wall.

Seal the openings

Seal any openings in the wall behind the range and

in the floor under the range after gas supply line is

installed.

Connect the range to the gas supply

Important: Remove all packing material and literature

from range before connecting gas and electrical

supply.

To prevent leaks, put pipe joint sealant on all external

pipe threads.

Your regulator is in location as shown in figure 9.

Do not allow regulator to rotate on pipe

when tightening fittings.

Connection to Pressure Regulator

The regulator is already installed on the appliance.

Do not make the connection too tight.

The regulator is die cast. Overtightening may crack the

regulator resulting in a gas leak and possible fire or

explosion.

Figure 8

• Tile countertops may need trim cut back 3/4"(1,9

cm) from each front corner and/or rounded edge

flattened (Figure 7).

• If the existing cutout width is greater than 30 1/16"

(76,4 cm), reduce the ¾" (1,9 cm) dimension.

• Countertop must be level. Place a level on the

countertop, first side to side, then front to back. If

the countertop is not level, the range will not be

level. The oven must be level for satisfactory baking

results. Cooktop sides of range fit over edges of

countertop opening.