Tech sheet abbreviations and terminology – FRIGIDAIRE FGIF3061NF User Manual

Page 4

Advertising
background image

Electronic Surface Element Control System (ESEC) Error Code Descriptions

When a specifi c error condition occurs in the ESEC system a code will be displayed in the electronic control panel. The error codes are displayed as
“EO
” in the left display followed by the code number in the right display. For each Error Code there is a listing of the likely cause or failure condition, as well as
suggested corrective actions to be taken. Always reset the power by disconnecting or turning off the power supply for 30 seconds to see if the failure condition will
clear. If the error code returns perform the steps one at a time in the order listed below to correct the specifi c failure condition. NOTE: If multiple changing error
codes are displayed check for disconnected wires or cables.

Tech Sheet Abbreviations and Terminology

EOC = Electronic Oven Control

ESEC = Electronic Surface Element Control

TST = Touch Sensor Technology (touch control glass panel)

UIB = User Interface Board

TSEC = Touch Sensor Electronic Control

RTD = Resistance Temperature Device. (Temp Probe or Temp Sensor)

VSC = Variable Speed Control

PS = Power Supply board (PS1 , PS2, etc.)

TCO = Thermal Cut Out also “Thermo Disc” or “Thermal Limiter”

Error
Code

Likely Cause or Failure
Condition

Suggested Corrective Action

11

Stuck key

1. Verify nothing is touching the potentiometer/display boards. Disconnect Power, wait 30 seconds and repower. If fault
returns: 2.Check/reseat connectors and harnesses between ESEC-UIB and potentiometer/display boards; 3. Replace
ESEC-UIB; 4. Replace potentiometer/display boards.

13

UIB Internal Failure

1. Replace UIB.

14

Potentiometer/display boards
connector

1. Disconnect Power, wait 30 seconds and repower. If fault returns: 2.Check/reseat connectors and harnesses
between ESEC-UIB and the potentiometer/display boards; 3. Replace ESEC-UIB; 4. Replace potentiometer/display
boards.

15

ESEC self-test failure

1. Verify cables and connections on the ESEC UIB are not damaged and are properly installed. If fault returns:
2.Check/reseat harnesses between ESEC-UIB and the potentiometer/display boards; 3. Replace ESEC-UIB; 4. Re-
place ESEC power supply board.

20/27

Communication failure be-
tween generator board and
UIB - left cooking zones

1. Verify communication harness between left and right side generator circuit board is not damaged and is properly in-
stalled; 2. Verify AC power harness is not damaged and is properly installed; 3. Verify ID1 jumper is properly installed;
4. Replace the UIB; 5. Replace the left side generator board.

21/28

Communication failure be-
tween generator board and
UIB - right cooking zones

1. Verify communication harness between left and right side generator circuit board is not damaged and is properly in-
stalled; 2. Verify AC power harness is not damaged and is properly installed; 3. Verify ID1 jumper is properly installed;
4. Replace the UIB; 5. Replace the right side generator board.

23

Communication failure be-
tween both generator boards
and UIB

1. Verify AC power supply to the appliance is 240V; 2. Verify communication harness between the ESEC UIB and the
left side generator board is not damaged and is properly installed; 3. Replace the UIB; 4. Replace both communication
harnesses; 5. Replace the left side generator board.

30, 35

AC input too high
AC input too low

1. Verify AC power supply to the appliance is 240V; 2. Verify cables and connections on the left side generator circuit
board are not damaged and are properly installed; 3. Replace the left side generator circuit board.

31, 32,
34, 36,
37, 40

Internal generator error

1. Verify cables and connections on the left side of the generator circuit board are not damaged and are properly
installed; 2. Replace the left side generator circuit board.

33

Cooling fan blocked

1. Verify cables and connections on the left side generator circuit board are not damaged and are properly installed;
2. Verify there is nothing touching or interfering with the fan on the left side generator circuit board; 3. Replace the left
side generator circuit board.

38

Cooling fan not connected

1. Verify fan is properly connected; 2. Replace the left side generator circuit board.

39

Confi guration error

1. Replace the ESEC UIB; 2. Replace both generator circuit boards.

41

Induction sensor (coils)
defect

1. Verify if the left side inductor (coils) are connected properly (measure approx. 0 Ohm); 2. Replace left side genera-
tor circuit board if 0 Ohm, otherwise replace the inductor (coil).

42, 43

General pot detection
Pot detection sensor failure

1. Verify pans are the proper material (magnet sticks to bottom of pan); 2. Verify pan is in the proper condition (not
warped, rusty); 3. Verify the pan is the proper size and placed correctly on the cooking zone. 4. Replace left side
generator circuit board.

44

Generator circuit board tem-
perature warning

1. Ensure cooktop is not being used with a dry pan at a high temperature setting; 2. Verify that installation follows the
installation instructions, check ventilation; 3. Allow zone to cool before continuing to cook.

45

Generator circuit board tem-
perature alarm

1. Ensure cooktop is not being used with a dry pan at a high temperature setting; 2. Verify that installation follows the
installation instructions, check ventilation; 3. Replace left side generator circuit board.

51
52
55
56

LF temp sensor failure
LR temp sensor failure
RF temp sensor failure
RR temp sensor failure

1. Verify induction temperature sensor is properly connected (see wiring diagram); 2. Verify the inductor temperature
sensor is properly installed and not damaged (measure approx. 100K Ohm at room temperature); 3. Replace applica-
ble generator circuit board, left or right (see wiring diagram).

63
64
67
68

LF temp sensor too hot
LR temp sensor too hot
RF temp sensor too hot
RR temp sensor too hot

1. Ensure cooktop is not being used with a dry pan at a high temperature setting; 2. Verify the inductor temperature
sensor is properly installed and not damaged (measure approx. 100K Ohm at room temperature); 3. Replace applica-
ble generator circuit board, left or right (see wiring diagram).

70
75

AC input too high
AC input too low

1. Verify AC power supply to the appliance is 240V; 2. Verify cables and connections on right side generator circuit
board are not damaged and are properly installed; 3. Replace the right side generator circuit board.

Error
Code

Likely Cause or Failure
Condition

Suggested Corrective Action

71, 72,
74, 76,
77, 80

Internal generator error

1. Verify cables and connections on the right side generator circuit board are not damaged and are properly installed;
2. Replace the right side generator circuit board.

73

Cooling fan blocked

1. Verify cables and connections on the right side generator circuit board are not damaged and are properly installed; 2.
Verify there is nothing touching or interfering with the fan on the right side generator circuit board; 3. Replace the right
side generator circuit board.

78

Cooling fan not connected

1. Verify fan is properly connected; 2. Replace the right side generator circuit board.

81

Induction sensor (coils)
defect

1. Verify if the right side inductor (coils) are connected properly (measure approx. 0 Ohm); 2. Replace right side generator
circuit board if 0 Ohm, otherwise replace the inductor (coil).

82
83

General pot detection
Pot detection sensor failure

1. Verify pans are the proper material (magnet sticks to bottom of pan); 2. Verify pan is in the proper condition (not
warped, rusty); 3. Verify the pan is the proper size and placed correctly on the cooking zone. 4. Replace right side
generator circuit board.

84

Generator circuit board tem-
perature warning

1. Ensure cooktop is not being used with a dry pan at a high temperature setting; 2. Verify installation follows the installation
instructions, check ventilation; 3. Allow zone to cool before continuing to cook.

85

Generator circuit board tem-
perature alarm

1. Ensure cooktop is not being used with a dry pan at a high temperature setting; 2. Verify installation follows the installation
instructions, check ventilation; 3. Replace right side generator circuit board.

Additional Failure Conditions

Symptom or Failure

Control Display

Possible Cause or Con-
dition

Suggested Corrective Action

Pan does not heat up.

Normal operation

Pan too small for proper pan
detection and only works
with low power.

Use larger pan or this pan on a smaller cooking zone. Refer to owners guide for
proper pan selection.

Flashing power
level Display and
pan does not heat.

Pan not detected.

Check whether the pots or pans are suitable for induction. Refer to owners guide
for proper pan selection.

Induction surface unit not
correctly connected or
surface unit open.

Check the surface unit wire terminal connections. Ensure that they are properly
connected and tightened. Test continuity of element (should be less than 1 ohm).

Distance between surface
unit and glass ceramic too
large.

Check whether the surface unit is properly positioned and touching the glass cooktop
surface.

Individual knobs/
controls cannot
be used or cannot
always be used.

None

1.

Test cables and
connections.

2. Potentiometer/display

boards defective.

3. UIB

defective.

1.

Follow instructions for proper use of controls.

2. Verify harness connections between UIB, and potentiometer/display boards.

Replace if defective or damaged.

3.

Replace potentiometer/display boards

4. Replace

UIB.

Cooking power too
low or shuts down
prematurely.

None

Fluids spilled or object lying
on control panel keypads.

Clean up spills or remove objects. Restart cooktop in normal manner.

Normal Operation

Ventilation slots obstructed.

Clear vent openings.

Unsuitable pots (bottom
bent).

Follow owner's guide for proper pan selection

.

Distance between surface
unit and glass ceramic too
large.

Check whether the surface unit is properly positioned and touching the glass cooktop
surface.

Fan does not start.

1.

With two cook zones operating, verify that the fan runs at a slow speed. If
fans do not run, check for foreign objects or stuck fan motor.

2.

Test continuity of motor windings. Replace motor if open.

3.

Replace induction control assembly.

Steady "HE" in
display when cooking
zone is cold and
switched off.

"HE"

Temperature sensor defect.

1.

Test surface unit RTD approx. 1K ohms at room temperature. Replace surface
unit if resistance is not correct.

2.

Replace induction control assembly.

Cooktop does not
initialize/operate.

Blank
No display
No beep

UIB not powered.

Verify installation and harness connections to UIB.

Defective UIB power supply
(PS2).

1.

Check for 120 volts AC at the power supply board connector

P1 between

pins 1 and 4. Test harness if voltage is not present.

2. Test for 8 volts DC output at the power supply board connector P3 between

Pins 1 and 2. Replace power supply board if voltage is not correct.

3.

Test for 16 volts DC at output at power supply board connector P3 between Pins
1 and 3. Replace power supply board if voltage is not correct.

Defective UIB.

Replace UIB.

Advertising